Club Chef Inc. - Executive Summary

| Accident History | Chemicals | Emergency Response | Registration | Source | Executive Summary |

Executive Summary 
 
Club Chef, Inc. Cincinnati, Ohio 45214 
 
The Accident Release Prevention and Emergency Response Policies 
 
Club Chef, Inc. has a long standing commitment to worker and public safety.  This commitment is demonstrated by the resources invested in accident prevention, such as training personnel and considering safety in the design, operation and maintenance of the facility's processes. 
 
This facility uses anhydrous ammonia as a refrigerant.  Anhydrous ammonia is considered hazardous by the EPA.  It is Club Chef, Inc. policy to adhere to all applicable Federal and State rules and regulations regarding hazardous materials, particularly anhydrous ammonia.  We have implemented reasonable controls to prevent a foreseeable release of ammonia. 
 
If an accidental release should occur, Club Chef, Inc. has trained personnel that will respond to control and contain the release.  We have also coordinated with the Hamilton County Local Emergency Planning Committee and Cincinnati Fire D 
epartment through annual filing of Sara Title III.  The Emergency Response Plan has provisions to notify these agencies should an incident occur that may affect the public. 
 
Stationary Sources and Regulated Substances Handled 
 
Club Chef, Inc. is a food processing plant for fresh cut produce.  Our process requires us to maintain an average plant temperature of 34 to38 degrees Fahrenheit. Anhydrous ammonia is the refrigerant used to maintain these low temperatures. 
 
Anhydrous ammonia is only used as a refrigerant.  Ammonia is the refrigerant of choice due to its low cost, efficiency and environmentally friendly make up.  The ammonia is housed within a closed loop system that removes heat from the interior of the facility at low temperatures and pressures.  Heat is then dispersed at high pressures and temperatures to the outside atmosphere. 
 
The refrigeration system at Club Chef, Inc. contains 13,500 pounds of anhydrous ammonia.  The refrigeration operation is a closed system with no purp 
oseful exposure to ammonia. 
 
Worst Case Scenario 
 
The worst case scenario for a toxic substance at Club Chef, Inc. is the release of 2,772 pounds of ammonia from the system's largest vessel, the High Pressure Receiver,  in a ten minute period.  The toxic endpoint was determined by using the RMP Comp computer modeling program and the Model Risk Management Program and Plan for Ammonia Refrigeration.  With a wind speed of 1.5 meters/second (3.4 miles/hour) and a Stability Class of  F in an urban topography the endpoint of the release was determined to be .5 miles from the receiver.  The plant is located in the West End of Cincinnati, Ohio.  The public receptors within a radius of .5 miles from the plant site include, schools, office buildings, churches, and a park.  
 
Alternate Case Scenario 
 
Alternate case scenarios for Club Chef, Inc. was reviewed by the refrigeration technician, the refrigeration contractor and the company's safety manager.  After discussing the operations of the refrig 
eration system we determined that a liquid pump seal failure at the re-circulator vessel would be the most probable cause of a leak.  A liquid pump seal failure would create a quarter inch orifice from which ammonia would escape at a rate of 88.9 pounds per minute.  At the systems pressures, it was determined that 889 pounds of ammonia would be released in a ten minute period.  Wind speeds of 3.0 m/sec and a stability class of D were used.  The toxic endpoint was determined to be.1 miles by using RMP Comp, ERPG-2 computer program. 
 
Five Year Accident History 
 
There have been no accidental releases of ammonia in the past five years that caused any deaths, injuries, or significant property damage to our facility.  There has been no accidental release of ammonia in the past five years that have resulted in off-site deaths, injuries, evacuations, sheltering in place, property damage or environmental damage. 
 
Release prevention program and Prevention Steps 
 
The accidental release program es 
tablished by Club Chef, Inc. is in compliance with The EPA, RMP, EPCRA and OSHA PSM.  Our program includes detection alarms, ventilation systems, trained technicians who perform routine equipment checks, and a trained Emergency Response Team.  The ERT has safety equipment readily accessible to respond to an accidental release.  The safety equipment includes air monitoring units (specifically for ammonia) personal protective equipment and self contained breathing apparatus.  The Hamilton County LEPC and Cincinnati Fire Department are aware that our facility houses anhydrous ammonia.  In the event of a catastrophic release of ammonia, plans with the Hamilton County LEPC and the Cincinnati Fire Department have been implemented for evacuation of any affected area. 
 
Emergency Response Plan 
 
Club Chef, Inc. has an emergency response plan to deal with emergencies that occur on site.  We have our own Emergency Response Team to handle an ammonia release.  Everyone on the team has been trained a 
t a minimum;  24 hour HAZMAT Technician level or 40 hour HAZMAT Incident Command level.  The Emergency Response Team is re-certified every year per OSHA regulations.  The team also conducts drills to maintain effectiveness.  We have coordinated with the Hamilton County LEPC and Cincinnati Fire Department through EPCRA and SARA Title III reporting requirements.
Click to return to beginning