FARMERS COOP ELEVATOR, DENMARK - Executive Summary

| Accident History | Chemicals | Emergency Response | Registration | Source | Executive Summary |

EXECUTIVE SUMMARY 
 
CENEX/LOL AGRONOMY COMPANY 
P.O. BOX 153 
SPEERY, IOWA  52650 
NEW LONDON FARMERS COOP-DENMARK LOCATION 
 
FOR FURTHER INFORMATION CONTACT:  DANIEL ANLICKER,MGR. 
 
1.  THE FACILITY POLICY 
 
    The owners, management, and employees of the CENEX/LOL AG.CO. are committed to 
     the prevention of any accidental releases of anhydrous ammonia.  If an accidental release should 
     occur, the facility is prepared to work with the local fire company, or other authorities,  to mitigate 
     any release and minimize the impact of the to people and the environment. 
 
2. FACILITY INFORMATION 
 
    The primary activity at the facility is the storage and blending of fertilizers for sale to farmers. 
 
    Anhydrous ammonia is received, stored, and distributed for direct application by the farmer or  
    custom application by the cooperative.  And for blending into mixed-grade fertilizers for crop 
     production nutrients, 
 
    The maximum quantity stored would be 154,500 pou 
nds in one 30,000 gallon storage tank.  We do  
    not receive anhydrous by rail. 
 
3. THE WORST-CASE RELEASE SCENARIO AND THE ALTERNATIVE RELEASE SCENARIO. 
 
    The worst-case release scenario would be the release of the total contents of a storage tank released 
     as a gas over 10 minutes.  The maximum quantity released would  be 131,132 pounds, which   
     represents the volume of the storage tank at 85 percent capacity as limited by design standards.  The 
     distance to the endpoint (point of dispersion to 200 ppm) is 2.56 miles. 
 
 
 
    The alternative release scenario based  on the most likely potential incident of a release from a break   
    in  transfer hose.  The distance the endpoint is .68 miles. 
 
4. THE ACCIDENTAL RELEASE PREVENTION PROGRAM. 
 
    The facility has implemented the provisions of "Safety Requirements for the Storage and Handling of 
    Anhydrous Ammonia, K-61.1, published by  The American National Standards Institute, Inc., and the 
 
standards of the U.S. Occupational Safety  and  Health Administration, 29 CFR 1910.111,  "Storage 
    and handling of anhydrous ammonia. 
 
5.  THE FIVE YEAR ACCIDENT HISTORY 
 
    There have been no accidental release of anhydrous ammonia in the past five years that: have caused 
    any deaths, injuries, or significant property damage at the facility; nor to our knowledge, have resulted    
    in offsite deaths, injuries, evacuations, sheltering in place, property damage, or environmental damage. 
 
 
 
 
 
 
 
 
 
6.   THE EMERGENCY RESPONSE PROGRAM. 
 
     THE FACILITY HAS: 
 
     a.    A written emergency action plan, in accordance with OSHA standard, 29 CRF 1910.38; 
            The plan was written by Regulator Consultants, Inc., Horton, KS. 
 
     b.     Provided state and local authorities the emergency planning and community right-to-know 
             information as required under SARA Title III (EPCRA) 
 
     c.     A written emergency response program, in accordance with OSHA standa 
rd, 29, CFR 1910.120 
             including pre-emergency planning and employee training. 
 
 
7.    PLANNED CHANGES TO IMPROVE SAFETY 
 
      Safety improvement is an on-going process at the facility.  Periodic evaluations are performed to  
      assess the maintenance of safe conditions.  There are no additional specific anhydrous ammonia 
      safety recommendations for implementation at this time.
Click to return to beginning