Tri-Con Industries, Ltd. Manufacturing Plant - Executive Summary

| Accident History | Chemicals | Emergency Response | Registration | Source | Executive Summary |

                     EXECUTIVE SUMMARY 
1.   SUMMARY OF OPERATION WHICH REQUIRES RMP 
 
  Tri-Con Industries, Ltd. Manufacturing Plant is a 
  recreational vehicle  seat  manufacturer. The scope  of 
  business  includes injection   molding,  polyurethane 
  foam  production,   vacuum forming,   sewing   and 
  assembly.  At  the  foam   production department we use a 
  mixture of 2,4 - Toluene Diisocyanate  and 2,6  - Toluene 
  Diisocyanate as a catalyst. There are two  5000 gallon 
  tanks to hold a catalyst mixture and a polyol. Because we 
  have more than minimum threshold for regulated 
  substances, 2,  4  and 2, 6 - TDI, Tri-Con Manufacturing 
  Plant is required to develop Risk Management Program. 
  Based on the modeling done with  RMP COMP and other 
  factors, Tri-Con Manufacturing  Plant is Level 2 program 
  for those two chemicals. 
  2,  4  and 2, 6 - TDI is contained in the 5000 gallon 
  holding tank,  a 55 gallon day tank, piping system which 
  connects  the day  t 
ank  and  the  foam head and the 
  foam  head  where  the catalyst  and the polyol are mixed 
  and shot into a  mold.  The chemical  is  delivered from 
  our supplier, Bayer,  by  a  tank truck  periodically. 
  The maximum quantity of 2, 4 and 2,  6  TDI  mixture 
  that Tri-Con stores at any time  is  about  5000 gallons, 
  which weighs about 50,000 pounds (2,4 - TDI   35,000 
  pounds, 2,6 - TDI 12,500 pounds respectively). 
 
2.   TRI-CON'S APPROACH TO CHEMICAL SAFETY 
 
  Tri-Con's management is committed to minimize negative 
  impact to  the  environment. As a way to ensure the 
  chemical  safety, Tri-Con is trying to be registered in 
  ISO 14001.  Through  ISO 14001, we can achieve continual 
  improvement by internal audit, corrective action and 
  management review. Training is  also  an important  part 
  of ISO 14001. Work instruction is set  up  for certain 
  processes.  Deviation from  the  procedure  and  work 
  instruction  will be pointed out by internal  audit 
,  and 
  the corrective  action  will take place. Maintenance 
  program  and emergency response procedures are also parts 
  of ISO 14001  and strictly followed. 
  Although ISO 14001 covers chemicals that are not part of 
  this Risk  Management  Program,  the  process  covered 
  under  Risk Management Program is one of the most 
  important aspects. 
 
 
3.    THE WORST-CASE RELEASE SCENARIO AND THE ALTERNATIVE 
RELEASE 
  SCENARIO 
 
  THE WORST-CASE SCENARIO 
 
     The  worst case scenario for our situation would be a 
     total release of  TDI mixture from the 5000 gallon 
     holding  tank. There are several possibilities for 
     this to happen, but  we based  our calculation on the 
     scenario that the valve  that is  located at the 
     bottom of the tank would rapture and the whole 
     content would be spilled. The size of  the  possible 
     rapture and the duration of the spill is described  in 
     the report.  The holding tank is located in a dike 
     tha 
t  would hold  the  whole  content from the tank. 
     The  modeling  of dispersion was done using RMP COMP 
     that we downloaded  from the  EPA  web  site. The 
     storage tank is  enclosed  in  the building  and the 
     dike that will hold the whole content  of the  tank , 
     thus reducing the chance of release outside  of the 
     facility. 
 
 
  THE ALTERNATIVE SCENARIO 
     The  alternative and most likely scenario is that the 
     pipe that 
     connects the day tank and the foam head would rapture 
     and  spill  the chemical. The size of the possible 
     rapture and  the  duration of the spill is described 
     in the report. If  this  type  of spill occurs, it 
     would  most  likely  be contained  fairly  quickly. As 
     soon as  we  shut  down  the system,  the pressure 
     will be balanced and  the spill  will stop.  What we 
     would lose is the chemical that  is  in  the piping 
     system, which is about 10 gallons. The spill  woul 

     happen  in  the  foam production area  where  there 
     is  no mitigation  system  but enclosure. The 
     modeling  was  done using  the  RMP COMP that we 
     downloaded from  the  EPA  web site. 
 
4.    THE  GENERAL  ACCIDENTAL  RELEASE  PREVENTION  PROGRAM 
AND 
  CHEMICAL-SPECIFIC PREVENTION STEPS 
 
     As  I  mentioned earlier, Tri-Con Industries,  Ltd. 
     has  a commitment  to  reduce negative environmental 
     impact.  The tool 
     that  we  use  is  ISO 14001. ISO  14001  Manual  and 
     Procedures  include process control, preventive 
     maintenance and 
     emergency  response  procedures.  ISO  14001,   would 
     require  Tri-Con  Industries,  Ltd.  to  achieve 
     continual improvement by utilizing internal audit, 
     corrective  action and  management review. Internal 
     audit would point out  any deviation from the required 
     preventive maintenance  program and  emergency 
     response procedures. When a non-conformance to  ISO 
 
     14001  Procedures is found, the corrective  action 
     will  take  place  and  the problem  will  be  solved. 
     The 
     management  periodically reviews  the  result  of 
     internal audit   and  Manual/Procedure  to  improve 
     on  the  system itself. 
     General  chemical safety for the process  that 
     applies  to RMP is a part of this ISO 14001 system. 
     We   also  plan  to  participate  in  voluntary 
compliance 
     program  offered  by  the State of Nebraska 
     Department  of Labor  every  year.  An inspector will 
     visit  our  facility and  conduct  an  inspection. 
     This  program  will  help  us identify  unsafe 
     conditions throughout the plant,  as  well as  the 
     department that has the covered process under  RMP. 
     Furthermore,  our  Safety Committee  will  conduct 
     monthly inspection. 
 
5.   THE FIVE-YEAR ACCIDENT HISTORY 
 
     We  have  not  have  any  accident  involving  the 
     covered process in the last 
five years. 
 
6.   THE EMERGENCY RESPONSE PROGRAM 
 
     The  emergency response program is set up for fire, 
     tornado and  chemical  spill.  The actual program  in 
     included  in this 
     report  as  a  Microsoft Word text  file.  (emergency 
     response procedure.txt) 
     In  the  event of chemical spill of 2,4 - and 2,6 
     TDI,  we will 
     evacuate the plant. The initial response will be done 
     by  City  of  Lincoln  Fire Department  Hazardous 
     Material team.  The  clean up will be contracted out 
     to  some  firms that 
     specialize in hazardous material clean up.  We  plan 
     to  have  a chemical spill drill involving the HAZMAT 
     team in  the fall of 1999. We plant to conduct a drill 
     at  least once a year. 
 
7.   PLANNED CHANGES TO IMPROVE SAFETY 
 
We  plan to  register in ISO 14001 in the fall  of  1999. 
Currently,  we  are  setting up an Environmental  Management 
System  manual and procedures, and training our associates 
. The 
integrity of the process system will be  checked  more frequently 
and  regularly. There is a  slight  possibility that  we  may 
switch to a different chemical with less  2,4 and 2,6 - TDI.
Click to return to beginning