Atkinson Fertilizer Inc. - Executive Summary |
Atkinson Fertilizer Inc. 302 N. Main St. Atkinson, Ne. 68713 For further information contact: Everett Vogel, Owner Risk Management Plan-EXECUTIVE SUMMARY 1. The Facility Policy The owners, management, and employees and employees of Atkinson Fertilizer Inc. are committed to the prevention of any accidental releases of anhydrous ammonia. If an accidental releases should occur, the facility is prepared to work with the local fire company, or other authorities, to mitigate any release and minimize the impact of the release to poeple and the environment. 2. Facility Information. -The primary activity at the facility is the storage and blending of fertilizers for sale to farmers. -Anhydrous ammonia is received, stored, and distributed for direct application for crop production nutrients. -The maximum quantity stored would be 102,000 pounds in our two-12,000 gallon storage tanks 3. The worst-case release scenario and the alternative release scenario. a. The worst-case release scenario would be the release of the total contents of the storage tank released as a gas over 10 minutes. The maximum quantity released would be 52,700 pounds, which represnets the volume of the storage tank at 85 percent capacity as limited by design standards. The distance to the endpoint (point of dispersion to 200 ppm) is 2.1 miles. b. The alternative release scenario based on the five-year accident history (or the most likely potential incident) is a release from a break in a transfer hose. The distance to the endpoint (point of disperion to 200 ppm) is 1.1 miles. 4. The accidental release prevention program. The facility has implemented the provisions of "Safety Requirements for the Storage and Handling of Anhydrous Ammonia, K-61.1", published by The American National Standards Institute, Inc., and the standards of the U.S. Occupational Safety and Health Administration (OSHA), 29 CFR 1910.111, "Storage and handling of anhydrous ammonia". 5. The Five-year Accident History a. There have been no accidental releases of anhydrous ammonia in the past five years that: - have caused any deaths, injuries, or significant property damage at the facility:nor - to our knowledge, have resulted in offsited deaths, injuries, evacuations, sheltering in place, property damage, or environmental damage. 6. The emergency response program. - The facility has: a. a written emergency action plan, in accordance with OSHA standard, 29 CFR 1910.38; c. provided state and local authorities the emergency planning and communtiy right-to-know information as required under SARA Title III (EPCRA). d. a written emergency response program, in accordance with OSHA standard, 29 CFR 1910.120, including pre-emergency planning and employee training. 7. Planned changes to improve safety. Safety improvement is an on-going process at the facility. Periodic evaluations are p erformed to assess the maintenance of safe conditions. There are no additional specific anhydrous ammonia safety recommmendations for iimplementation at this time. |