Clyde Cooperative Association - Executive Summary

| Accident History | Chemicals | Emergency Response | Registration | Source | Executive Summary |

EXECUTIVE SUMMARY 
 
CLYDE COOPERATIVE ASSOCIATION 
DEER CREEK, OKLAHOMA 
 
For further information contact: General Manager 
 
Risk Management Plan - EXECUTIVE SUMMARY 
 
1. The Facility Policy 
 
The owners, management, and employees of Clyde Cooperative Association (Renfrow) are committed to the prevention of any accidental releases of anhydrous ammonia.  If an accidental release should occur, the facility is prepared to work with the local fire company, or other authorities, to mitigate any release and minimize the impact of the release to people and the environment. 
 
2. Facility Information 
 
7 Anhydrous ammonia is received, stored, and distributed for direct application for crop production nutrients. 
7 The maximum quantity stored would be 182,962 pounds in our two storage tanks one 30,000 gallon and one 12,000 gallon.  
 
3. The worst-case release scenario and the alternative release scenario. 
 
a. The worst-case release scenario would be the release of the total contents of a storage tank (or  
tank car) released as a gas over 10 minutes.  The maximum quantity released would be 131,325 pounds, which represents the volume of the largest storage tank at 85 percent capacity as limited by design standards.  The distance to the endpoint (point of dispersion to 200 ppm) is 2.50 miles. 
b. The alternative release scenario based on the five-year accident history (or the most likely potential incident) is a release from a break in a transfer hose.  The distance to the endpoint (point of dispersion to 200 ppm) is .83 miles. 
 
4. The accidental release prevention program 
 
The facility has implemented the provisions of "Safety Requirements for the Storage and Handling of Anhydrous Ammonia, Kk-611.1", published by The American National Standards Institute, Inc., and the standards of the U.S. Occupational Safety and Health Administration (OSHA), 29 CFR 1910.111, "Storage and handling of Anhydrous Ammonia". 
 
5. The Five-year Accident History  
 
a. There have been no accidental releases of anhy 
drous ammonia in the past five years that: 
 
7 Have caused any deaths, injuries, or significant property damage at the facility; nor 
7 To our knowledge, have resulted in offsite deaths, injuries, evacuations, sheltering in place, property damage, or environmental damage. 
 
 
6. The Emergency Response Program 
 
The facility has: 
 
a. A written Emergency Action Plan, in accordance with OSHA standard, 29 CFR 1910.38; 
 
b. Provided state and local authorities the emergency planning and community right-to-know information as required under SARA Title III (EPCRA). 
 
c. A written emergency response program, in accordance with OSHA standard 29 CFR 1910.120, including pre-emergency planning and employee training. 
 
 
7. Planned Changed to Improve Safety 
 
Safety improvement is an on-going process at the facility.  Periodic evaluations are performed to assess the maintenance of safe conditions.  There are no additional specific anhydrous ammonia safety recommendations for implementation at this time.
Click to return to beginning