Montrose Potato Growers Cooperative Association - Executive Summary

| Accident History | Chemicals | Emergency Response | Registration | Source | Executive Summary |

             Risk Management Plan (RMP) - Ammonia 
                      Executive Summary 
       Montrose Potato Growers Cooperative Association 
                      Montrose, Colorado 
 
 1. Accidental Release Prevention and Emergency Response Policies 
We at Montrose Potato Growers Cooperative Association in Montrose are strongly committed to 
employee, public, and environmental safety.  This commitment is an inherent part of our 
comprehensive accidental release prevention program that covers areas such as design, installation, 
operating procedures, maintenance, and employee training associated with the processes at our 
facility.  It is our policy to implement appropriate controls to prevent possible releases of regulated 
substances.  If such a release does occur, our trained emergency response personnel are at hand to 
control and mitigate the effects of the release.  We also coordinate our response efforts with the 
Montrose Fire Department, which pr 
ovides additional emergency response expertise. 
 
 2. Stationary Source and Regulated Substances Handled 
Our facility's primary activities include support services for crop production.  We have anhydrous 
ammonia stored in a 30,000 -gallon tank  at our facility in Montrose (Figure 1).  The maximum 
amount stored is 25500 gallons (131223 pounds) at the maximum fill capacity of 85 %. 
 
 3. Worst Case Release and Alternative Release Scenarios 
We utilized RMP PRO for the worst case and alternate case scenarios of the required offsite 
consequence analysis for our facility.  The following details these scenarios. 
 
The worst case release scenario involves a catastrophic release of the entire contents of the           
anhydrous ammonia storage tank (131223 pounds) in gaseous form over a 10-minute period.  At 
Class F atmospheric stability, 1.5 m/s wind speed, and a urban topography, the maximum distance 
to a toxic endpoint of 0.14 mg/L is 5.2 miles (Figure 2).  The estimated population within a 5 
.2-mile 
radius of this facility is 13,000. 
 
The alternative release scenario involves a release from an anhydrous ammonia product line.  The 
scenario involves the release of 7616.42  pounds of ammonia in a gaseous form over a period of 30 
minutes.  Under neutral weather conditions, the maximum distance to the toxic endpoint of 0.14 
mg/L of ammonia is 0.31 mile (Figure 3).  The estimated population within a 0.31-mile radius of the 
facility is 2,000. 
 
 4. General Accidental Release Prevention Program 
Our facility has taken all the necessary steps to comply with the EPA's accidental release prevention 
requirements as set forth in 40 CFR part 68.  The following sections briefly describe the elements 
of the release prevention program that is in place at our stationary source. 
 
 
 
Process Safety Information 
Montrose Potato Growers maintains a detailed record of safety information that describes the 
chemical hazards, operating parameters, and equipment designs associated with all processes 
(A 
ppendix D). 
 
Process Hazard Analysis 
Our facility conducts comprehensive studies to ensure that hazards associated with our processes are 
identified and controlled effectively.  Any findings from the hazard analysis are addressed in a 
timely manner. 
 
Operating Procedures 
Montrose Potato Growers maintains written operating procedures to ensure that activities within our 
covered processes are conducted safely.  These procedures address various modes of operation; the 
information is regularly reviewed and is readily accessible to operators involved in the processes 
(Appendix B). 
 
Training 
Montrose Potato Growers has a comprehensive training program in place to ensure that employees 
who are operating processes are competent in the operating procedures associated with these 
processes. 
 
Mechanical Integrity 
Montrose Potato Growers conducts documented maintenance checks on process equipment to ensure 
proper operation.  Maintenance checks are conducted by qualified personnel with previous trai 
ning 
in maintenance practices.  Examples of process equipment that would receive maintenance checks 
include:  pressure vessels, storage tanks, piping systems, relief and vent systems, emergency 
shutdown systems, controls, and pumps.  Any equipment deficiencies identified by the maintenance 
checks are corrected in a safe and timely manner (Appendix C). 
 
Management of Change 
Written procedures are in place at Montrose Potato Growers to manage changes in process 
chemicals, technology, equipment, and procedures.  Process operators, maintenance personnel or 
other employees whose job tasks are affected by a modification in process conditions are promptly 
notified of the modification and offered training to deal with it. 
 
Pre-startup Reviews 
Montrose Potato Growers routinely conducts pre-startup safety reviews related to new processes and 
modifications in established processes.  These reviews are conducted to confirm that construction, 
equipment, and operating and maintenance procedures are s 
uitable for safe startup prior to placing 
equipment into operation. 
 
Compliance Audits 
Montrose Potato Growers conducts compliance audits on a regular basis to determine whether the 
plan's provisions, set out under the 40 CFR part 68, are being implemented.  Any non-compliance 
issue discovered during the audit is promptly corrected. 
 
Employee Participation 
Montrose Potato Growers truly believes that process safety management and accident prevention is 
a team effort.  Company employees are strongly encouraged to express their views concerning 
accident prevention issues and to recommend improvements.  In addition, our employees have access 
to all information created as part of the facility's implementation of the RMP, particularly 
information resulting from process hazard analyses. 
 
 5. Five-year Accident History 
Montrose Potato Growers has had an excellent record of preventing accidental releases over the last 
5 years.  Due to our stringent release prevention policies, no accidental re 
lease has occurred during 
this period. 
 
 6. Emergency Response Plan 
Montrose Potato Growers maintains a written emergency response plan to deal with accidental 
releases of hazardous materials.  The plan addresses all aspects of emergency response including first 
aid and medical treatment, evacuations, and notification of local emergency response agencies and 
the public (Appendix A).
Click to return to beginning