meadowland farmers coop - Executive Summary |
MEADOWLAND FARMERS COOP BOX 396 WALNUT GROVE MN 56180 FOR FURTHER INFORMATION CONTACT RICHARD MARTIUS MGR PHONE 507-859-2281 RISK MANAGEMENT PLAN- EXECUTIVE SUMMARY 1. THE FACILITY POLICY THE OWNERS, MANAGEMENT AND EMPLOYEES OF MEADOWLAND FARMERS COOP ARE COMMITTED TO THE PREVENTION OF ANY ACCIDENTAL RELEASES OF ANHYDROUS AMMONIA. IF AN ACCIDENTAL RELEASE SHOULD OCCUR, THE FACILITY IS PREPARED TO WORK WITH THE LOCAL FIRE COMPANY, OR OTHER AUTHORITIES, TO MITIGATE ANY RELEASE AND MINIMIZE THE IMPACT OF THE RELEASE TO POEPLE AND THE ENVIRONMENT. 2. FACILITY INFORMATION THE PRIMARY ACTIVITY AT THE FACILITY IS THE STORAGE AND BLENDING OF FERTILIZERS FOR SALE TO FARMERS. ANHYDROUS AMMONIA IS RECEIVED, STORED AND DISTRIBUTED FOR DIRECT APPLICATION. ANHYDROUS AMMONIA IS USED FOR CROP PRODUCTION NUTRIENTS. THE MAXIMUM QUANTITY OF AMMONIA STORED WOULD BE 250000 POUNDS IN OUR 2 12000 GALLON STORAGE TANKS AND NURSE TANKS. THE MAXIMUM QUANTITY HANDLED WOUL D BE THE UNLOADING OF A TANK TRUCK HOLDING 40000 POUNDS. 3. THE WORST CASE RELEASE SCENARIO AND THE ALTERNATIVE RELEASE SCENARIO. a. THE WORST CASE RELEASE SCENARIO FOR ANHYDROUS AMMONIA WOULD BE THE RELEASE OF THE TOTAL CONTENTS OF A STORAGE TANK RELEASED AS A GAS OVER TEN MINUTES. THE MAXIMUM QUANTITY RELEASED WOULD BE 55000 POUNDS WHICH REPRESENTS THE VOLUME OF THE STORAGE TANK AT 85 PERCENT CAPACITY AS LIMITED BY DESIGN STANDARDS. THE DISTANCE TO THE ENDPOINT ( POINT OF DISPERSION TO 200 PPM) IS .78 MILES. B. THE ALTERNATIVE RELEASE SCENARIO FOR ANHYDROUS AMMONIA BASED ON THE HAZARD REVIEW IS A TWO MINUTE RELEASE FROM A BREAK IN A THREE INCH PIPE. THE DISTANCE TO THE ENDPOINT (POINT OF DISPERSION IS .78 MILES. 4. THE ACCIDENTAL RELEASE PREVENTION PROGRAM. THE FACILITY HAS IMPLEMENTED THE PROVISIONS OF "SAFETY REQUIREMENTS FOR THE STORAGE AND HANDLING OF ANHYDROUS AMMONIA, K-61.1", PUBLISHED BY THE AMERICAN NATIONAL STANDARDS INSTITUTE INC. AND THE S TANDARDS OF THE U.S. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), 29 CFR 1910.111, "STORAGE AND HANDLING OF ANHYDROUS AMMONIA". IN ADDITION, MINNESOTA DEPT. OF AG RULES. 5. THE FIVE YEAR ACCIDENT HISTORY A. THERE HAVE BEEN NO ACCIDENTAL RELEASES OF ANHYDROUS AMMONIA IN THE PAST FIVE YEARS THAT: HAVE CAUSED ANY DEATH, INJURIES, OR SIGNIFICANT PROPERTY AT THE FACILITY; NOR TO OUR KNOWLEDGE, HAVE RESULTED IN OFFSITE DEATHS, INJURIES, EVACUATIONS, SHELTERING IN PLACE, PROPERTY DAMAGE OR ENVIROMENTAL DAMAGE. 6. THE EMERGENCY RESPONSE PLAN THE FACILITY HAS; A. A WRITTEN EMERGENCY ACTION PLAN, IN ACCORDANCE WITH OSHA STANDARD, 29 CFR 1910.38 B. PROVIDED STATE AND LOCAL AUTHORITIES THE EMEGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW INFORMATION AS REQUIRED UNDER SARA TITLE III (EPCRA) C.COORDINATED WITH LOCAL EMERGENCY RESPONDERS. 7.PLANNED CHANGES TO IMPROVE SAFETY SAFETY IMPROVEMENTS IS AN ON-GOING PROCESS AT THE FACILITY. PERIODIC EVALUATIONS ARE PERF ORMED TO ASSESS THE MAINTENANCE OF SAFE CONDITIOPNS. THERE ARE NO ADDITIONAL SPECIFIC ANHYDROUS AMMONIA SAFETY RECOMMENDATIONS FOR IMPLEMENTATION AT THIS TIME. |