PIERCEVILLE ELEVATOR - Executive Summary

| Accident History | Chemicals | Emergency Response | Registration | Source | Executive Summary |

GARDEN CITY CO-OP, INC. 
PIERCEVILLE ELEVATOR 
RISK MANAGEMENT PLAN- EXECUTIVE SUMMARY 
 
1.  FACILITY POLICY 
    THE OWNERS, MANAGEMENT, AND EMPLOYEES OF THE PIERCEVILLE ELEVATOR, GARDEN CITY CO-OP, INC. ARE COMMITTED TO THE PREVENTION OF ANY ACCIDENTAL RELEASES OF ANHYDROUS AMMONIA.  IF AN ACCIDENTAL RELEASE SHOULD OCCUR, THE FACILITY IS PREPARED TO WORK WITH THE LOCAL FIRE DEPARTMENT AND OTHER AUTHORITIES TO MITIGATE ANY RELEASE AND MINIMIZE THE IMPACT OF THE RELEASE TO PEOPLE AND THE ENVIRONMENT. 
 
2.  FACILITY INFORMATION 
    THE PRIMARY ACTIVITIES AT THE THE FACILITY ARE TO RECIEVE, STORE, AND MERCHANDIZE GRAIN AND THE STORAGE OF ANHYDROUS AMMONIA TO BE SOLD TO FARMERS FOR CROP PRODUCTION.  THE MAXIMUM QUANTITY STORED WOULD BE 110,000# IN ONE 26,000 GAL. TANK. 
 
3.  THE WORST CASE RELEASE SCENARIO AND THE ALTERNATIVE RELEASE SCENARIO. 
    A.  THE WORST CASE RELEASE SCENARIO WOULD BE THE RELEASE OF THE CONTENTS OF THE STORAGE TANK RELEASED AS A GAS OVER 10 MINUTES.  THE MAXIMUM QUANT 
ITY RELEASED WOULD BE 110,000 #, WHICH REPRESENTS THE VOLUME OF THE STORAGE TANK AT 85 PERCENT CAPACITY AS LIMITED BY DESIGN STANDARDS.  THE DISTANCE TO THE ENDPOINT (POINT OF DISPERSION TO 200PPM) IS 2.40 MILES.  THERE ARE HOMES WITHIN THE ENDPOINT HOUSING 100 PEOPLE. 
    B.  THE ALTERNATIVE RELEASE SCENARIO BASED ON THE MOST LIKELY POTENTIAL INCIDENT IS A RELEASE FROM A BREAK IN A TRANSFER HOSE.  THE DISTANCE TO THE ENDPOINT (POINT OF DISPERSION TO 200 PPM) IS 0.83 MILES. THERE ARE HOMES WITHIN THE ENDPOINT HOUSING 100 PEOPLE IF PROPER LOW WIND AND HIGH HUMIDITY CONDITIONS EXISTED. 
 
4.  THE ACCIDENTAL RELEASE PREVENTION PROGRAM 
    WE HAVE IMPLEMENTED THE PROVISIONS OF "SAFETY REQUIREMENTS FOR THE STORAGE AND HANDLING OF ANHYDROUS AMMONIA, K-61.1" PUBLISHED BY THE AMERICAN NATIONAL STANDARDS INSTITUTE, INC., AND STANDARDS OF THE U.S. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), 29 CFR 1919.111, "STORAGE AND HANDLING OF ANHYDROUS AMMONIA". 
 
5.  THE FIVE-YEAR ACCIDENT HISTOR 

    THERE HAVE BEEN NO ACCIDENTAL RELEASES OF ANHYDROUS AMMONIA IN THE PAST FIVE YEARS THAT HAVE CAUSED ANY DEATHS, INJURIES, OR SIGNIFICANT PROPERTY DAMAGE AT THE FACILITY; NOR TO OUR KNOWLEDGE, HAVE RESULTED IN OFFSITE DEATHS, INJURIES, EVACUATIONS, SHELTERING IN PLACE, PROPERTY DAMAGE, OR ENVIRONMENTAL DAMAGE. 
 
6.  THE EMERGENCY RESPONSE PROGRAM 
    THE FACILITY HAS A WRITTEN EMERGENCY ACTION PLAN, IN ACCORDANCE WITH OSHA STANDARD, 29 CFR 1910.38, HAS PROVIDED STATE AND LOCAL AUTHORITIES THE EMERGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW INFORMATION AS REQUIRED UNDER SARA TITLE III (EPCRA), AND HAS A WRITTEN EMERGENCY RESPONSE PROGRAM, IN ACCORDANCE WITH OSHA STANDARD, 29 CFR 1910.120, INCLUDING PRE-EMERGENCY PLANNING AND EMPLOYEE TRAINING. 
 
7.  PLANNED CHANGES TO IMPROVE SAFETY. 
    SAFETY IMPROVEMENT IS AN ON-GOING PROCESS AT THE FACILITY.  PERIODIC EVALUATIONS ARE PERFORMED TO ASSESS THE MAINTENANCE OF SAFE CONDITIONS.  THERE ARE NO ADDITIONAL SPECIFIC ANHYDROUS AMMONIA SAFE 
TY RECOMMENDATIONS FOR IMPLEMENTATION AT THIS TIME.
Click to return to beginning