MORRILL ELEVATOR, INC. - Executive Summary

| Accident History | Chemicals | Emergency Response | Registration | Source | Executive Summary |

NEW ANHYDROUS AMMONIA PLANT INSTALLATION 
 
EXPECTED STARTUP DATE 4-1-2000 
 
 
FOR FURTHER INFORMATION CONTACT: J.R. ISCH, PLANT MANAGER 
 
Risk Management Plan - EXECUTIVE SUMMARY 
 
1. The Facility Policy 
 
    The owners, management, and employees of Morrill Elevator, Inc. are committed to the prevention of 
any accidental releases of anhydrous ammonia.  If an accidental release should occur, the facility is prepared to work with the local fire company, or other authorities, to mitigate any release and minimize the impact of the release to people and the environment. 
 
2.  Facility information 
 
    - The primary activity at the facility is the storage of fertilizers for the sale to farmers. 
 
    - Anhydrous ammonia is received, stored and distributed for direct application for crop production nutrients. 
 
    - The maximum quantity stored would be 120,000 pounds in our 30,000 gallon storage tank. 
 
3.  The worst-case release scenario and the alternative release scenario 
 
    a.  The worst-c 
ase release scenario would be the release of the total contents of a storage tank released as a gas over 10 minutes. The maximum quantity released would be 120,000 puonds, which represents the volume of the largest storage tank at 85 percent capacity as limited by design standards.  Thedistance to the endpoint (point of dispersion to 200 ppm) is 1.48 miles. 
 
    b.  The alternative release scenario based on the five-year accident history (or the most likely potential incident) is a release from a break in a transfer hose.  The distance to the endpointpoint of dispersion to 200 ppm) is .6 miles. 
 
4.  The accidental release prevention program 
 
    The facility has implemented the provisions of "Safety Requirements for the Storage and Handling of Anhydrous Ammonia, -81.1", published by The American National Standards Institute, Inc., and the standards of the U. S. Occupational Safety and Health Administration (OSHA), 29 CFR 1910.111, "Storage and handling of anhydrous ammonia". 
 
5.  The 
Five-year Accident 
 
    There have been no accidental releases of anhydrous ammonia on the past five years that: 
    -have caused any deaths, injuries, or significant property damage at the facility; nor 
    -to our knowledge, have resulted in offsite deaths, injuries, evacuations,sheltering in place, property damage, or environmental damage. 
 
6.  The emergency response program 
 
    - The facility has: 
 
    a.  A written emergency action plan, in accordance with OSHA standard, 29 CFR 1910.38 
 
    b.  Provided state and local authorities the emergency planning and community Right-to-know information as required under SARA Title III (EPCRA). 
 
    c.  A written emergency response program, in accordance with OSHA standard, 29 CFR 1910.120, including pre-emergency planning and employee training. 
 
7.  Planned changes to improve safety 
 
    Safety improvement is an on-going process at the facility.  Periodic evaluations are performed to assess the maintenance of safe comditions.  The 
re are no additional specific anhydrous ammonia safety recommendations for implementation at this time.
Click to return to beginning