Western Farm Service, Lamont - Executive Summary |
Agrium / Western Farm Service Lamont Facility 1. Facility Accidental Release Policy The owners, management, and employees of Western Farm Service's Lamont facility (herein referred to as the Facility) at 7th & Sprague, Lamont, Washington 99017 are committed to the prevention of any accidental release of anhydrous ammonia. If an accidental release should occur, the facility is prepared to work with the local fire department, or other authorities to mitigate any release and minimize the impact of the release to people and the environment. A detailed emergency response plan has been developed and will be implemented in the event of an accidental release. 2. Facility Information The primary activity at the Facility is the storage, blending, and sale of fertilizers, in addition to, the sale of pre-packaged agricultural chemicals to farmers. Anhydrous ammonia is received, stored, and distributed for direct application for crop production nutrients. Anhydrous ammonia is stored i n one 12,200-gallon storage tank (bullet) at the site. The maximum quantity of anhydrous ammonia handled in this process is 62,220 pounds. 3. The Worst-Case Release Scenario and Alternative Release Scenario A. Anhydrous Ammonia Worst-Case and Alternative Release Scenarios The worst-case release scenario is failure of the largest storage tank when filled to the greatest amount releasing 48,960 pounds of anhydrous ammonia, which represents the volume of the largest storage tank at 85% capacity as limited by regulations. The distance to the endpoint (point of dispersion to 200 ppm) is 1.73 miles. The alternative release scenario, based on the PHA scenarios (or the most likely potential incident) and is a release of 26,638 pounds of anhydrous ammonia from a broken 3-inch diameter pipe. The distance to the endpoint (point of dispersion to 200 ppm) is 1.56 miles. 4. Accidental Release Prevention Program Anhydrous Ammonia: The Facility has implemented the provisions of the " Safety Requirements for Storage and Handling of Anhydrous Ammonia, K-61.1", published by the American National Standards Institute, Inc.; and the standards of the U.S. Occupational Safety and Health Administration (OSHA), 29 CFR 1910.111, "Storage and Handling of Anhydrous Ammonia." 5. Five-year Accident History a. There have been no accidental releases or near misses of anhydrous ammonia in the past five years that: 1. Have caused any deaths, injuries, or significant property damage at the facility; nor 2. Have resulted in off-site deaths, injuries, evacuations, sheltering in place, property damage, or environmental damage. 6. The Emergency Response Program The facility's emergency response program was written in accordance with the following regulations: OSHA 29 CFR 1910.38; OSHA 29 CFR 1910.120; and 7. Planned Changes to Improve Safety |