Logan Agri-Service, Inc. - Executive Summary

| Accident History | Chemicals | Emergency Response | Registration | Source | Executive Summary |

1. The Facility Policy:  The owners, management, and employees of Logan Agri-Service, Inc. are committed to the prevention of any accidental releases of anhydrous ammonia by utilization of proper equipment, regular inspections and maintenance and training of all persons that work with the material. Should an accidental release occur, the facility has orientated the local fire department and the local emergency planning committee so they can plan for response to any release and minimize the impact of the release to people and the environment. 
 
2. Facility Information:  The primary activity at the facility is the storage of anhydrous ammonia for sale to farmers.  Anhydrous ammonia is received, stored, and distributed for direct application as a crop production nutrient.  The maximum quantity stored would be 60,000 pounds in a single storage tank. 
 
3. The worst-case release scenario would be the release of the total contents of the storage tank release as a gas over 10 minutes.  The maxim 
um quantity release would be 51,000 pounds, which represents the volume of the storage tank at 85 percent capacity as limited by design standards and company procedures.  The distance to the endpoint of dispersion based on the model used is 1.75 miles. 
 
The alternative-case release scenario is assumed to be a release from the rupture of a 1 inch transfer hose, with 2900 pounds release over 2 minutes.  The distance to the endpoint of dispersion is .64 miles. 
 
4. The accidental release program:  The facility complies with the Rules and Regulations relating to The Handling of Anhydrous Ammonia and Low Pressure Nitrogen Solutions, Equipment, Containers and Storage Facilities.  These regulations administered by the Illinois Department of Agriculture are consistent with ANSIK61.1 and OSHA 29 CFR1910.111 regarding storage and handling of anhydrous ammonia. 
 
5. The Five-year Accident History:  There have been no accidental releases of anhydrous ammonia for the covered process in the past five  
years that have caused any deaths, injuries, or significant property damage on site; nor to our knowledge, have any accidental releases resulted in offsite deaths, injuries, evacuations, sheltering in place, property camage or environmental damage. 
 
6. The Emergency Response Program:  The facility has a written emergency action plan in accordance with OSHA standard 29 CFR 1910.38 and provides state and local suthorities the emregency planning and community right-to-know information as required under SARA Title III of EPCRA.  Our emergency response action plan has been reviewed with the local fire department and provided to the local emergency planning committtee for coordination in the community response planning. 
 
7. Planned changes to improve safety:  Safety improvement is an on-going process at the facility.  Periodic evaluations are performed to assess the maintenance of safe practices and operations.  There are no additional specific anhydrous ammonia safety recommendations for im 
plementation at this time.
Click to return to beginning