KRAGNES FARMERS ELEVATOR COMPANY - Executive Summary

| Accident History | Chemicals | Emergency Response | Registration | Source | Executive Summary |

KRAGNES FARMERS ELEVATOR CO. 
RR 1 BOX 217 
MOORHEAD, MN  56560-9751 
 
FOR FURTHER INFORMATION CONTACT DENNIS BROMLEY, GENERAL MANAGER, 218-233-4257 
 
RISK MANAGEMENT PLAN- EXECUTIVE SUMMARY 
 
1.  THE FACILITY POLICY 
 
    THE OWNERS, MANAGEMENT, AND EMPLOYEES OF KRAGNES FARMERS ELEVATOR ARE COMMITTED TO THE PREVENTION OF ANY ACCIDENTAL RELEASES OF ANHYDROUS AMMONIA.  IF AN ACCIDENTAL RELEASE SHOULD OCCUR, THE FACILITY IS PREPARED TO WORK WITH THE LOCAL FIRE DEPARTMENT, OR OTHER AUTHORITIES, TO MITIGATE ANY RELEASE AND MINIMIZE THE IMPACT OF THE RELEASE TO PEOPLE AND THE ENVIRONMENT. 
 
2.  FACILITY INFORMATION 
 
    THE PRIMARY ACTIVITY AT THE FACILITY IS THE STORAGE OF FERTILIZERS FOR SALE TO FARMERS.  
 
    ANHYDROUS AMMONIA IS RECEIVED, STORED AND DISTRIBUTED FOR DIRECT APPLICATION.  ANHYDROUS AMMONIA IS USED FOR CROP PRODUCTION NUTRIENTS. 
 
    THE MAXIMUM QUANTITY OF AMMONIA STORED WOULD BE 260,000 POUNDS IN OUR TWO 30,000 GALLON STORAGE TANKS.  THE MAXIMUM QUANTITY HANDLED WOULD BE THE 
UNLOADING OF A TANK TRUCK HOLDING 40,000 POUNDS. 
 
3.  THE WORST CASE RELEASE SCENARIO AND THE ALTERNATIVE RELEASE SCENARIO. 
 
    A.  THE WORST CASE RELEASE SCENARIO FOR ANHYDROUS AMMONIA WOULD BE THE RELEASE OF THE TOTAL CONTENTS OF A STORAGE TANK RELEASED AS A GAS OVER TEN MINUTES.  THE MAXIMUM QUANTITY RELEASED WOULD BE 130,000 POUNDS, WHICH REPRESENTS THE VOLUME OF THE STORAGE TANK AT 85% CAPACITY AS LIMITED BY DESIGN STANDARDS.  THE DISTANCE TO THE ENDPOINT (POINT OF DESPERSION TO 200 PPM) IS 1.12 MILES. 
 
    B.  THE ALTERNATIVE RELEASE SCENARIO FOR ANHYDROUS AMMONIA BASED ON THE HAZARD REVIEW IS A 2 MINUTE RELEASE FROM A BREAK IN A 3 INCH PIPE.  THE DISTANCE TO THE ENDPOINT (POINT OF DESPERSION TO 200 PPM) IS .78 MILES. 
 
4.  THE ACCIDENTAL RELEASE PREVENTION PROGRAM. 
 
    THE FACILITY HAS IMPLEMENTED THE PROVISIONS OF "SAFETY REQUIREMENTS FOR THE STORAGE AND HANDLING OF ANHYDROUS AMMONIA, K-61.1, " PUBLISHED BY THE AMERICAN NATIONAL STANDARDS INSTITUTE, INC. AND THE STANDARDS  
OF THE U.S. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), 29 CFR 1910.111, "STORAGE AND HANDLING OF ANHYDROUS AMMONIA."  IN ADDITION, MINNESOTA DEPT. OF AG. RULES. 
 
5.  THE FIVE YEAR ACCIDENT HISTORY 
 
    THERE HAVE BEEN NO ACCIDENTAL RELEASES OF ANHYDROUS AMMONIA IN THE PAST FIVE YEARS THAT: 
    HAVE CAUSED ANY DEATHS, INJURIES, OR SIGNIFICANT PROPERTY DAMAGE AT THE FACILITY:  NOR TO OUR KNOWLEDGE, HAVE RESULTED IN OFFSITE DEATHS, INJURIES, EVACUATIONS, SHELTERING IN PLACE, PROPERTY DAMAGE OR ENVIRONMENTAL DAMAGE. 
 
6.  THE EMERGENCY RESPONSE PROGRAM 
 
    THE FACILITY HAS: 
 
    A.  A WRITTEN EMERGENCY ACTION PLAN, IN ACCORDANCE WITH OSHA STANDARD, 29 CFR 1910.38 
 
    B.  PROVIDED STATE AND LOCAL AUTHORITIES THE EMERGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW INFORMATION AS REQUIRED UNDER SARA TITLE III (EPCRA). 
 
    C.  COORDINATED WITH LOCAL EMERGENCY RESPONDERS. 
 
7.  PLANNED CHANGES TO IMPROVE SAFETY 
 
    SAFETY IMPROVEMENT IS AN ON-GOING PROCESS AT THE FACILITY.  PERIO 
DIC EVALUATIONS ARE PERFORMED TO ASSESS THE MAINTENANCE OF SAFE CONDITIONS.  THERE ARE NO ADDITIONAL SPECIFIC ANHYDROUS AMMONIA SAFETY RECOMMENDATIONS FOR IMPLEMENTATION AT THIS TIME.
Click to return to beginning