City of Camden WTP - Executive Summary

| Accident History | Chemicals | Emergency Response | Registration | Source | Executive Summary |

City of Camden Water Treatment Plant 
 
1.  Accidental release prevention and emergency response policies: 
 
The City of Camden Water Treatment Plant accidental release prevention policy involves a unified approach that integrates technologies, procedures, and management practices.  Accidental release prevention is a function of the safety devices (technology) inherent in the facility design, safe material handling practices used (procedures), and commitment to training of plant employees (management practices).  All applicable requirements of the U.S. Environmental Protection Agency (EPA) Risk Management Prevention Program (40 CFR 68.65-87) are adhered to.  It is the goal of the City of Camden Water Treatment Plant to ensure plant and community safety through an aggressive program of hazard analysis, preventive maintenance, equipment testing, standard operating procedures, and employee training. 
 
The City of Camden Water Treatment Plant emergency response policy involves the preparation  
of a emergency preparedness plan which is tailored to the facility and to the emergency response services available in the community.   The emergency preparedness program includes procedures for notification of the City of Camden Fire Department HAZMAT Team (off-site mutual aid response), LEPC (community response plan), and SCDHEC (state response plan).  The City of Camden Water Treatment Plant emergency preparedness program is based upon recommendation of the American Water Works Association (AWWA) and the Chlorine Institute and is in compliance with the EPA Risk Management Emergency Response Program (40 CFR 68.90) requirements. 
 
2.  Stationary source and regulated substances handled: 
 
The regulated substance handled and used at the City of Camden Water Treatment Plant is chlorine.  The Maximum intended inventory of chlorine at the facility at anytime is 16,000 pounds (8 ton containers).   
 
The City of Camden Water Treatment Plant provides potable water for residential, retail, and in 
dustrial use through out the City of Camden service area.  Chlorine is used in the water treatment process to destroy nuisance and pathogenic microorganisms in the wastewater (i.e., chlorine use as a water disinfectant is an industry standard).  The chlorination process includes chlorine container handling and storage facilities, chlorine feed system (vacuum chlorinators, piping, and injectors), and related safety equipment and instrumentation.  The City of Camden Water Treatment Plant is manned 24-hours a day and access to the plant site is restricted to authorized personnel. 
 
3.  Worst-case release scenario and the alternative release scenario:  
 
The worst-case release scenario is defined by EPA as the release of the maximum quantity of a regulated substance from a process vessel or pipe line failure that will result in the greatest distance to the designated endpoint.  The probability of the release occurring is not considered, it is just assumed to happen.  The worst-case chlorine  
release scenario at the City of Camden Water Treatment Plant involves a catastrophic failure of a one ton chlorine container and the predicted release of 2,000 pounds of chlorine to the atmosphere.  The offsite consequence analysis for this scenario was performed following conditions pre-defined by EPA, namely release of the entire amount of chlorine as gas in 10 minutes, chlorine toxic endpoint of 0.0087 mg/l (i.e., the maximum airborne concentration below which it is believed that nearly all individuals could be exposed for up to one hour without experiencing or developing irreversible or other serious health effects or symptoms which could impair an individuals ability to take protective action), and worst-case weather conditions (i.e., stable atmospheric conditions and a wind speed of 1.5 m/s).  Also, no administrative or passive mitigation systems were considered in this scenario.  The DEGADIS+ computer model was used to perform this consequence analysis.  The results of the conse 
quence analysis performed for the hypothetical worst-case chlorine release scenario did predict an offsite impact. 
 
EPA describes the alternative release scenario as simply a more realistic release than the worst-case release or a release that is more likely to occur than the worst-case release.  The alternative release scenario chosen for the City of Camden Water Treatment Plant involves a break in a 1/4-inch chlorine manifold pigtail resulting in the predicted release of 1,000 pounds of chlorine over a one hour period into an enclosure and then to the atmosphere.  The alternative chlorine release scenario chosen for the City of Camden Water Treatment Plant was selected based on the results of a qualitative risk analysis of possible release alternatives.  The offsite consequence analysis for this scenario incorporated less stable weather conditions (i.e., Stability D and wind speed of 3.0 m/s), passive mitigation (i.e., enclosure) and active mitigation (i.e., actuation of chlorine lea 
k detector and emergency response by offsite mutual aid responders to control the leak).  The DEGADIS+ computer model was used to perform this consequence analysis.  The results of the consequence analysis performed for the hypothetical alternative chlorine release scenario did predict an offsite impact. 
 
While EPA requires analysis of the consequence of a worst-case release scenario, worst-case scenarios as defined by the EPA have an extremely low probability of occurrence.  The worst-case release could only happen if the majority of the safety and technology features in use failed at the same time. Additionally, it would have to occur at exactly the time the worst-case weather conditions also existed, a most improbable event.  Further, certain mandated consequence conditions such as the entire amount of chlorine will be released as a gas in ten minutes and comparison of a ten minute release to a toxic endpoint based on a one-hour exposure value are unrealistic.  However, there is no  
allowance in the EPA Risk Management Program (RMP) rule for making an adjustment to the worst-case release scenario conditions.  For this reason, the alternative release scenario should be the focus of prevention and preparedness efforts.   
 
4.  General accidental release program and the chemical-specific prevention steps: 
 
The City of Camden Water Treatment Plant complies with EPA's RMP rule, OSHA's Process Safety Management standard (29 CFR 1910.119), and with all applicable state and local codes and regulations.  The chlorination process was constructed, and is operated, in accordance with recommendations of the AWWA and Chlorine Institute.  The City of Camden Water Treatment Plant accidental release prevention program is based on the following key elements: 
 
     High level of training for operators and maintenance personnel 
     Equipment inspection, testing, and preventive maintenance 
     Use of "industry standard" process and safety equipment 
     Use of accurate and effective operatin 
g procedures 
     Performance of hazard review of equipment and procedures 
     Implementation of an internal and external auditing program 
     Segregation of chemical processes for compatibility and fire prevention/control 
     Chlorine leak detectors and alarm system 
     Availability of SCBAs and chlorine container leak repair kit 
     Maintenance of approved parts inventory 
 
5.  Five-year accident history: 
 
The City of Camden Water Treatment Plant is a new facility (placed on-line 5/4/99) and as such has no five year accident history.  Since going on-line, the plant has experienced no accidental releases of chlorine. 
 
6.  Emergency Response Program: 
 
The City of Camden Water Treatment Plant has an emergency preparedness plan that is integrated with the LEPC plan.  The City of Camden Water Treatment Plant maintains a mutual aid agreement with the City of Camden Fire Department HAZMAT Team to provide emergency response services in the event of a chlorine release.  Emergency response exercises a 
re conducted on a routine  basis.  The plant emergency preparedness plan includes procedures for the notification of offsite mutual aid responders, LEPC, SCDHEC, and the public along with a discussion of actions to be taken in the event of a chlorine release.  The plan also addresses first aid and medical treatment. 
 
7.  Planned changes to improve safety: 
 
The last Process Hazard Analysis (PHA) was performed in April, 1999 and it resulted in no recommended process or operational changes.