HEWITT BROTHERS, INC. - Executive Summary

| Accident History | Chemicals | Emergency Response | Registration | Source | Executive Summary |

HEWITT BROTHERS, INC. 
RISK MANAGEMENT PLAN - EXECUTIVE SUMMARY 
(FOR FURTHER INFORMATION CONTACT STUART WOOD) 
 
1.  THE FACILITY POLICY 
 
    THE OWNERS, MANAGEMENT, AND EMPLOYEES OF HEWITT BROTHERS, INC. ARE COMMITTED TO  
    THE PREVENTION OF ANY ACCIDENTAL RELEASES OF ANHYDROUS AMMONIA.  IF AN ACCIDENTAL 
    RELEASE SHOULD OCCUR, THE FACILITY IS PREPARED TO WORK WITH THE LOCAL FIRE COMPANY 
    OR OTHER AUTHORITIES, TO MITIGATE ANY RELEASE AND MINIMIZE THE IMPACT OF THE RELEASE 
    TO PEOPLE AND THE ENVIRONMENT. 
 
2.  FACILITY INFORMATION 
 
    WE ARE AN AGRI BUSINESS COMPANY.  WE MANUFACTURE AND SELL ANIMAL FEEDS.  WE ALSO 
    SELL PETROLEUM PRODUCTS, SEEDS, FERTILIZER, CHEMICALS AND ANHYDROUS AMMONIA. 
 
    -ANHYDROUS AMMONIA IS RECEIVED, STORED, AND DISTRIBUTED FOR DIRECT APPLICATION FOR 
     CROP PRODUCTION NUTRIENTS. 
 
    -THE MAXIMUM QUANTITY STORED WOULD BE 84,000 POUNDS IN OUR 12,000 AND 8,000 GALLON 
     STORAGE TANKS, AND OUR 9  DELIVERY WAGONS.  THE MAXIMUM HANDLED WO 
ULD BE THE 
     UNLOADING OF A TANK TRUCK HOLDING 36,000 POUNDS. 
 
3.  THE WORST CASE RELEASE SCENARIO AND THE ALTERNATIVE RELEASE SCENERIO 
 
    A)  THE WORST CASE RELEASE SCENARIO WOULD BE THE RELEASE OF THE TOTAL CONTENTS 
          OF OUR 12,000 GALLON STORAGE TANK RELEASED AS A GAS OVER 10 MINUTES.  THE MAX. 
          QUANTITY RELEASED WOULD BE 51,000 POUNDS, WHICH REPRESENTS THE VOLUME OF THE  
          LARGEST STORAGE TANK AT 85% CAPACITY AS LIMITED BY DESIGN STANDARDS.  THE 
          DISTANCE TO THE ENDPOINT (POINT OF DISPERSION TO 200 PPM) IS 0.79 MILES. 
 
    B)  THE ALTERNATIVE RELEASE SCENERIO BASED ON THE MOST LIKELY POTENTIAL INCIDENT 
          IS A RELEASE FROM A BREAK IN A TRANSFER HOSE.  THE DISTANCE TO THE END POINT 
          (POINT OF DISPERSION TO 200 PPM) IS 0.56 MILES. 
 
4.  THE ACCIDENTAL RELEASE PREVENTION PROGRAM 
 
    THE FACILITY HAS IMPLEMENTED THE PROVISIONS OF "SAFETY REQUIREMENTS FOR THE  
    STORAGE AND HANDLING OF ANHYDROUS AMMONIA, K-61.1", PUBLIS 
HED BY THE AMERICAN 
    NATIONAL STANDARDS INSTITUTE, INC., AND THE STANDARDS OF THE U.S. OCCUPATIONAL 
    SAFETY AND HEALTH ADMINISTRATION (OSHA), 29 CFR 1910.111, "STORAGE AND HANDLING 
    OR ANHYDROUS AMMONIA". 
 
5.  THE FIVE YEAR ACCIDENT HISTORY 
 
    THERE HAVE BEEN NO ACCIDENTAL RELEASES OF ANHYDROUS AMMONIA IN THE PAST FIVE 
    YEARS THAT HAVE CAUSED ANY DEATHS, INJURIES, OR PROPERTY DAMAGE AT THE FACILITY 
    NOR TO OUR KNOWLEDGE, HAVE RESULTED IN OFFSITE DEATHS, INJURIES, EVACUATIONS, 
    SHELTERING IN PLACE, PROPERTY DAMAGE, OR ENVIRENMENTAL DAMAGE. 
 
6.  THE EMERGENCY RESPONSE PROGRAM 
 
    THE FACILITY HAS: 
 
    A)  A WRITTEN EMERGENCY ACTION PLAN, IN ACCORDANCE WITH OSHA STANDARD, 29 CFR  
          1910.38 
 
    B)  PROVIDED STATE AND LOCAL AUTHORITIES THE EMERGENCY PLANNING AND COMMUNITY  
          RIGHT-TO-KNOW INFORMATION AS REQUIRED UNDER SARA TITLE III (EPCRA) 
 
    C)  A WRITTEN EMERGENCY RESPONSE PROGRAM, IN ACCORDANCE WITH OSHA STANDARD, 
          29 CFR 1 
910.120, INCLUDING PRE-EMERGENCY PLANNING AND EMPLOYEE TRAINING 
 
7.  PLANNED CHANGES TO IMPROVE SAFETY 
 
    SAFETY IMPROVEMENT IS AN ON-GOING PROCESS AT THE FACILITY.  PERIODIC EVALUATIONS 
    ARE PERFORMED TO ASSESS THE MAINTENANCE OF SAFE CONDITIONS.  THERE ARE NO  
    ADDITIONAL SPECIFIC ANHYDROUS AMMONIA SAFETY RECOMMENDATIONS FOR IMPLEMEN- 
    TATION AT THIS TIME.
Click to return to beginning