CENTRAL IOWA COOP-STANHOPE - Executive Summary

| Accident History | Chemicals | Emergency Response | Registration | Source | Executive Summary |

Risk Management Plan - Executive Summary 
 
Facility:    CENTRAL IOWA COOP 
Contact:    DAVID HALVERSON 
Phone:        515/826/3225 
 
1. Facility Policy. 
 
The owners, management and employees of CENTRAL IOWA COOP AT STANHOPE (the facility) are committed to the prevention of any accidental releases of  
anhydrous ammonia    and  propane. 
If an accidental release should occur, the facility is prepared to work with the local fire department, or other authorities, to mitigate and minimize the impacts of the release to the people and the environment.   
 
2. Facility Information. 
 
The primary activity at the facility is the storage and blending of fertilizers for sale to farmers.  Anhydrous ammonia is received, stored and distributed for direct application for crop production nutrients. 
 
Anhydrous ammonia    is / are stored at the facility in 3 storage tanks           ( 26, 000 gallons (1), 18, 000 gallons (2),).  
The maximum quantity stored would be 246,170 pounds.  
 
Propane is/are stored at facility in 2 stor 
age (30,000 gallons (2),) 
   The maximum quantity stored would be 221,000 pounds. 
 
3.    Worst-Case Scenario and Alternate Release Scenario 
 
a.    The worst-case scenario would be the release of the total contents of a storage tank released as gas over a period of 10 minutes.  The maximum quantity released would be 113,800 pounds, which represents the volume of the largest storage tank at 85 percent capacity as limited by design standards.  The distance to the end point (point of dispersion to 200 parts per million, or ppm) is 2.43 miles.   
 
b.    The alternate release scenario, based on the five-year accident history (or the most likely potential incident), is a release from a break in a transfer hose.  The distance to the endpoint (point of dispersion to 200 ppm) is 1.56 miles.   
 
4.    Accidental Release Prevention Program 
 
The facility has been reviewed for general compliance with the provisions of "Safety Requirements for the Storage and handling of Anhydrous Ammonia, K-61.1", published by The  
American National Standards Institute, Inc. (ANSI), and the standards of the U.S. Occupational Safety and Health Administration (OSHA), 29 CFR 1910.111, "Storage and handling of anhydrous ammonia".  The ANSI Standard has been adopted by reference by Iowa Administrative Code Part 21-Chapter 43-Rule 43.6(200)-Standard for the storage and  handling of anhydrous ammonia.  The OSHA standard is referenced in the Registration Form Section 8.3.b. 
 
5.    Five-Year Accident History.         
 
There have been no accidental releases of  anhydrous ammonia or propane 
in the past five years that: have caused any deaths, injuries or significant property damage at the facility; nor to our knowledge, have resulted in off-site deaths, injuries, evacuations, sheltering in place, property damage, or environmental damage.   
 
    
 
6.    Emergency Response Program. 
 
   The facility has: 
 
   a.    a written action plan, in accordance with OSHA standard 29 CFR 1910.38; 
 
b.    provided state and local authorities with the emergency plan 
ning and community right-to-know information as required under SARA Title III (EPCRA); 
 
   c.    a written emergency response program, in accordance with OSHA standard  
29 CFR 1910.120, including pre-emergency planning and employee training. 
 
7.    Planned Changes to Improve Safety. 
 
Safety improvement is an on-going process at the facility.  Periodic evaluations are performed to assess the maintenance of safe conditions.   
 
There are no additional specific safety recommendations regarding storage or use of anhydrous ammonia  and  propane  for implementation at this time.
Click to return to beginning