Sundance Ag. - Executive Summary

| Accident History | Chemicals | Emergency Response | Registration | Source | Executive Summary |

                      Executive Summary 
                         Sundance Ag. 
 
    Sundance Ag. Inc, a division of Sundance Resources of Phoenix, Ariz. began production 
at the Burley facility in August of 1996.  We produce the pesticide, Metam Sodium under the 
trade name of Sectagon 42.  The raw materials used in the process are water, Monomethylamine, 
Carbon Disulfide, and Sodium Hydroxide.     
    The water is pumped from the ground, treated to make it suitable for the process, and 
added as needed. 
    The Carbon Disulfide and Monomethylamine arrive at the site by rail car, while the 
Sodium Hydroxide may arrive by either rail car to tanker truck. 
    The finished product is shipped from the plant by either tanker truck or railcar. 
 
    The plant is divided into three separate areas.  To the east is the receiving and storage 
area for the raw materials.  Here the material is received in rail cars, or tanker trucks carrying the 
Sodium Hydroxide.   
The cars are spotted at the appropriate tower for the unloading.  We use 
two towers, one for Carbon disulfide, and one for the amine and Sodium Hydroxide.   This 
separation of unloading towers allow us to fit each tower with fittings and equipment specific to 
each type of chemical.  This prevents any possible mixing of chemicals in the storage tanks. 
    Upon arrival, the tank cars are spotted at the proper tower for unloading.   Grounding 
straps are attached and checked to prevent any sparking from static electricity while unloading is 
occurring.   The system is also configured such that the transfer pumps will not start unless the 
grounding is complete.  The fittings are attached to the cars, and tested for tightness.  All tools 
used in the opening and closing are spark-less, thus again preventing accidental ignition of any 
flammable vapors.  The system is pressure checked with an inert gas, nitrogen, and the cars 
pressurized with the same gas.  This again prevents any accidental i 
gnition. 
    The cars are unloaded into the proper storage areas.  The tanks are dedicated tanks, 
holding only the chemical stated on them. We have the capability of storing over 328,000 
gallons of Carbon Disulfide at any one time. .  Similarly,  we have the capacity for 65,000 
gallons of the amine, but there is rarely this much on hand at any one time.   
     There is never any cross mixing of storage chemicals.  All tanks are grounded, held 
under an inert gas atmosphere, and monitored.  The thickness of the metal is checked on an 
annual basis with a non-destructive technique to verify that the chemicals are not corroding the 
walls, leading to a hazardous situation.  All tanks are equipped with pressure relief devices and 
rupture disks set to release before a pressure increase would rupture the tank.  These devices are 
checked on a routine basis. 
 
    A computer modeling program was used to assess the possible damage to the area and 
the environment from an accidental release of the 
stored chemicals.  There were two scenarios 
ran for both Carbon Disulfide and Monomethylamine: A 'worst case' scenario, and a secondary, 
more realistic one.   
    The "Worst Case" scenario for Carbon Disulfide was the total failure of a storage tank, 
releasing the entire amount of 54,000 gallons into the containment berm.   For this scenario, it 
was assumed that the entire spill occurred within ten minutes, the air temperature was the 
highest recorded in the area for the last five years (100 F), and the wind was blowing at 3 yards 
per second.  Under this scenario, the area of concern stretched for 11 miles.  This would include 
the entire town of Burley, provided the wind direction was correct.   A secondary scenario was 
ran using the same conditions, only using the actual conditions that would occur under our 
control and response plans.  Under this scenario, the area of concern was only 0.6 miles.  
Another scenario was ran, using the conditions of a small leak from a broken pipe givi 
ng a hole 
of less then two square inches.  This gave an area of concern of only 0.2 miles. 
    A similar computer scenario was ran for the amine.  The main difference between the 
two was that the Carbon Disulfide is considered a toxic liquid, while the amine is considered to 
yield an explosive cloud that ignites.  Under the "Worst Case" scenario, the release of an entire 
tank of 32,000 gallons, with the resultant explosion, the area of influence of the explosion, or the 
area of damage was 0.2 miles.   Similarly, the scenario of a leaking pipe, with the resultant fire 
ball gave an area of damage of 0.1 miles. 
    To mitigate these types of damages, the storage areas are equipped with a number of 
safety devices to monitor and prevent any release of the chemical.    The storage tanks are 
enclosed in concrete berms that would contain any spill from the tank in a small area, thus 
limiting the surface area of the liquid, and thus slowing down the amount released.  In addition, 
both storage 
areas have the capability of being showered with copious amounts of water to 
knock down, and contain vapors that may be released.   
    The storage area for the Carbon Disulfide has one additional safety feature.   Since the 
chemical is heavier then water, the containment berm has had installed a deluge system and 
monitoring detectors.  If the detectors sense the chemical above a set amount well below any 
danger level, but signaling a possible leak, they set off an alarm in the central computer system.  
This alarm opens the deluge system flooding the containment area to a depth of over ten inches 
of water in less then ten minutes.  The Carbon Disulfide will be submerged by the water, totally 
limiting the amount of vapors that are released from the site.    
    The raw materials are brought into the central processing area under redundant computer 
control and inert gas blanket where they are combined to produce the product.  The entire 
mixing process in controlled, measured, and moni 
tored by computers.  Any deviation from a set 
of defined values causes an alarm to sound, alerting the operators to the problem.   From the 
central control room, the entire plant may be shut down to a safe condition in just seconds.  
    Following processing, which includes an added step to remove any unreacted raw 
materials, the product goes into storage, where it awaits shipment. 
 
 
    Sundance Ag., both employees and management, place a great deal of emphasis on both 
safety and environmental protection. We feel that these go hand in hand.   All operators at the 
site are given extensive training in response to both chemical spills and safety hazards.  All 
operators are trained to a Hazmat Technician level by schooling certified by the State of Idaho 
Bureau of Emergency Response.  In addition, all are trained in CPR and First Aid.  We hold 
numerous training sessions, dry runs, and full response exercises to keep these skills up to date.  
We have, on site, many pieces of emergency re 
sponse equipment.  Until just recently, we were 
the best trained and equipped hazardous materials response personnel in the entire Mini-Cassia 
area.  We train  in connection with both the local fire department, sheriff's office, hospital, and 
local emergency planning committee.  This assures that all people who may have to respond to 
an incident at the site are well acquainted and able to function as a team.  This assures both 
Sundance Ag., and our neighbors in Cassia county the highest degree of protection in the event 
of a hazardous chemical incident. 
 
    In April of 1997, shortly after we began production, we experienced an incident.  A 
storage tank of product, which inadvertently contained a flammable combination of chemicals, 
somehow ignited.  The result was the injury of one employee who was responding to the 
emergency. This employee later died in the hospital.   There was about 12,000 gallons of product 
released to the environment.  Emergency responders were called, and respon 
ded.   Thanks to the 
work that had been done in safety training, the results were kept to a minimum, with no 
hazardous chemicals escaping the site. 
    Since that time, the entire plant and process has been re-designed and re-built.  The 
computer control system has been installed.  The process has been altered, by additional 
equipment and processing steps, to assure that the final product going into storage is as safe as 
possible.  This has resulted in, not only better product, but less waste that has to be disposed of 
by transporting to waste treatment facilities.  An effect that helps everyone. 
    We also took the accident as a wake up call to beef up the training and the response 
ability.  We added paperwork and training pursuant to OSHA's   Process Safety Management 
program.  We established response documents, detailing to operators specific steps to be taken 
in the event of a release or hazardous materials incident.  These are taught, tested, and trained on 
constantly.  We curr 
ently are in the process of making application to OSHA to be accepted into 
their Voluntary Protection Program (VPP).  This would make us one of only a handful of 
companies in Idaho to achieve this status. 
 
    The end result of all this work is a very complete response plan, extensive review and 
concentration on safety by both management and personnel, a highly trained and effective 
response team, and excellent working relations with local emergency response personnel. 
                                     
9.0 EMERGENCY ACTION PLAN 
 
 
 
1.0 PROCEDURE  
 
    The purpose of this procedure is to provide information on the handling and mitigation of 
    emergencies within the plant. Evacuation plans and emergency response plans are 
    identified and detailed. 
 
 
2.0 SCOPE  
 
This procedure covers the Burley facility and all employees working at that facility, 
 
 
3.0 REFERENCES 
 
    3.1  OSHA 29 CFR 1910.38  Employee Emergency Action Plans  
    3.2  OSHA 29 CFR 1910.119 Process Safety 
Management 
    3.3   OSHA 29 CFR 1910.120 Hazardous Waste Operations and Emergency Response 
    3.4   OSHA 29 CFR 1910.165 Employee Alarm Systems. 
    3.5  EPA 40 CFR Part 68 Subpart G - Risk Management Planning 
 
4.0   RESPONSIBILITY / ACCOUNTABILITY  
 
    4.1  The Plant Manager is responsible for the implementation of this procedure. 
 
    4.2   The Safety Manager shall insure that: 
 
     4.2.1 All employees are trained in this procedure.  
 
    4.2.2 That the emergency alarm system is tested on a periodic basis.  
 
    4.2.3 That all documentation of training and testing is maintained.  
 
5.0  DEFINITIONS  
 
5.1  Emergency Alarm -- A distinctive and recognizable signal which is capable of being 
    perceived above ambient noise and light levels by all employees in the workplace. 
5.2 Emergency Responders-Supervisors and employees trained in emergency response in 
    accordance with 29 CFR 1910.120.  
5.3  Incident Levels--Incident levels are determined by estimating the nat 
ure of the response 
    required to manage them safely, with minimal environmental impact and minimal 
         property                          damage. 
 
    5.3.1      Level I Incident--Any incident quickly managed via the use of emergency 
              responders which are immediately available.  
 
    5.3.2     Level II Incident--Any accident, injury, fire, spill or chemical release requiring 
              resources not immediately available or any incident with significant impact 
              outside the plant boundary.  
 
5.4  Non-critical personnel--Personnel who can be immediately evacuated from a plant area 
    without needing to take the time to shut down processes or equipment.  
 
5.5  On-Scene Command (OSC)--on scene command during an emergency incident will be 
    the responsibility of the senior trained supervisor present.  
 
 
6.0  PROCEDURE  
 
6.1  Fire and medical assistance  
 
    6.1.1      To report a fire or to obtain medical assistance contact the Control Roo 
m via 
              radio. If outside assistance is needed call 911. 
 
     6.1.2 On reporting an emergency provide the following minimum information and stay on 
the line if possible. For a fire emergency use an outside fine, cellular or car phone if it is not safe 
to use one of the phones inside the building.  
 
    A.   State the emergency. (Fire, Medical, etc.)  
 
    B.   Give the location  
 
    C.   Give your name and phone number.  
 
    D.   Give location of emergency if different than from where you are calling  
 
    E.    Answer any questions the dispatcher may have,  
 
    F.    Stay on the fine, if possible, until told by the dispatcher to hang up.  
 
6.2  Medical Emergencies.  
 
    6.2.1      Employees within the vicinity of the emergency shall provide assistance within 
              their abilities and training.  
 
                   6.2.2     All medical emergencies shall be reported to the supervisor immediately.       6.2.3    If outside medical assistance is 
needed, call 911. Any employee at the scene has 
              the authority to call 911, but the call should be made through the office, if 
              possible, so that repeat calls are not made.  
 
    6.2.4     An injured or sick employee, no matter how minor the problem, shall NOT be sent 
              to obtain medical assistance by themselves. If it is determined that medical 
              assistance is desired but the concern is not serious enough to warrant a call to 911, 
              a second employee or other responsible individual shall accompany the employee.  
 
6.3  Emergency Evacuation,  
 
    6.3.1      When the evacuation alarm sounds all employees shall leave the plant by the 
              nearest exit (exit path). (See map, attachment 1) 
 
    6.3.2      All employees shall report to the assembly area for head count. The primary 
              assembly area is the grass area at the fork in the plant road, southwest of the 
              facility. The secondar 
y assembly area is the equipment "graveyard" to the 
              northeast of the facility. Stay out of the way of traffic and responding emergency 
              equipment.  
 
    6.3.3     All supervisors shall take a head count to determine if all personnel are present. 
              The results of the head count shall be forwarded to the senior person present.  
 
    6.3.4     Know your location and the locations of all exit paths. Study the evacuation maps 
              posted in the plant.  
 
    6.3.5     Alarm maintenance.  
 
    A.   The evacuation alarm shall be tested a minimum of once a week.  
 
    B.    A different "pull station" shall be used for each test. 
 
6.4  Fire emergency -- Fire fighting.  
 
    6.4.1     Only those employees trained in fire extinguisher usage shall attempt to use a fire 
              extinguisher.  
 
    6.4.2     The alarm shall be pressed BEFORE any attempt is made to fight a fire 
 
    6.4.3      No attempt shall be made to fight a fire w 
ith fire extinguishers unless it is obvious 
              that the fire can be controlled with a fire extinguisher.  
 
    6.4.4     Always ensure a direct way out (not past the fire) when using a fire extinguisher.  
 
    6.5  Emergency Response Drills 6.6.3    Incident Response - Level II Incident Response (for larger incidents)  
 
         A.   Triggering event - the need for a Level II response is triggered when the       
              plant emergency alarm sounds. Level II incidents shall be managed in 
              accordance with the guidelines described in the following: 
 
 
         B.    Response  
 
    B.1       On Scene Command (OSC) 
 
    B.1.1     Responsibility & Authority - until such a time as a more 
              senior member of plant management establishes an Incident 
              Command System, the On Scene Command (OCS) shall 
              assume the responsibility and authority of the Incident 
              Commander. 
 
     B. 1.2  
  Coordinate Emergency Response Activities - The 
              supervisor shall manage the incident using available plant 
              resources. If additional plant or community resources are 
              required, the supervisor shall request them from the Incident 
              Commander. 
 
     B. 1.3   Manage Spills & Releases - If there is a release, the 
              supervisor shall see that it is reported in accordance 
              with reporting requirements. 
 
    B.1.3.1   Specific actions should be taken to prevent 
              major releases of hazardous chemicals into 
              the environment.  These actions are: 
 
    B.1.3.2   Only personnel trained in the hazards of the 
              chemicals and in hazardous materials 
              response (40 hr, Hazmat Tech) should be 
              allowed to respond.. 
 
    B.1.3.3   The first objective is to equip all responding 
              personnel with proper PPE.  This will be up 
              to th 
e safety officer, using information found 
              in Appendices A, B and C of this document. 
 
    B.1.3.4   Responding personnel should first attempt to 
              contain the release. Prevent any more 
              chemical from being released then is 
              necessary.   
    `                             B.1.3.4.1 If the deluge system in the 
                                            CS2 has not activated, open it 
                                            manually. 
    B.1.3.4.2 If the leak is from MMA, open 
              the fire water monitor, and 
              flood the tanks with spray to 
              contain the mist.   
    B.1.3.5        Stop the leak. Do this by what ever means 
                   possible, eg shut a valve, close a pipe, plug a 
                   hole, etc. 
 
    B.1.3.6   After the leak is stopped. Contain the spill, 
              confining it to as small an area as possible. 
 
     B. 1.4    Communications - Communication sh 
all be maintained by 
              radio and if needed, by telephone with outside sources.  
 
    B.2  Plant Management - Shall report to the Incident Command Center 
         (established as described in the next section.)  
 
    B.3  Plant Employees - All Level II responses require that a headcount be taken. 
         This shall be done as described in Section 6.3.2.  
 
6.6.4     Incident Response - Establishing a Formal Incident Command System (ICS) 
 
    An Incident Command System shall be set up as described in the following:  
 
    A.    The Incident Commander shall be the Plant Manager or his or her designee. In the 
         absence of this person, the incident commander shall be the senior person present. 
         The Incident Commander shall be trained in Emergency Response and the Incident 
         Command System.  
 
              B.   The Incident Commander shall see that personnel are assigned to the           Officer, Coordinator and Chief jobs indicated in Figure I ( 
individuals can 
              be assigned to more than one job). Whether or not every job needs to be 
              filled depends on the nature of the incident. However, the Incident 
              Commander shall assume the responsibilities of any jobs left unassigned.  
 
    C.   Once completed, Figure 1, Table 1 & Table 2 shall be posted in the Incident 
         Command Center.  
 
    D.   The Incident Commander shall see that each Officer receives a copy of Table I and 
         each Chief receives a copy of Table 2.  
 
    E.   The Incident Commander, Chiefs and Officers shall respond to the incident in 
         accordance with their training (and in conformance with the responsibilities 
         indicated in Tables 1&2).  
 
    6.6.5     Incident Response - Mutual Aid and Outside Agencies  
 
    A.    Mutual Aid - Sundance Ag does not have any Mutual Aid Agreement,  
 
    Note: the Incident Commander must approve the use of non-Sundance Ag                 
              res 
ources on-site.  
 
    B.   Outside Agencies - The following table is a partial list of outside agencies which 
         can provide support in the event of a release of a hazardous material  
 
 
 
Name 
Contact Information 
 
 
County Sheriff 
911                 678-2252 
 
 
County Fire Department 
911                 678-7371 
 
 
Memorial Hospital 
911                  678-4444 
 
 
State Comm 
1-800-632-8000 
 
 
SE Idaho Hazardous Material Response Team 
1-208-234-6100 
Pocatello Fire Department 
 
.                   
        Figure 1 - Sundance Ag, Burley, Idaho - Incident Command System (ICS) 
 
Fill in Officer & Chief names & post this diagram (along with Tables 1 &2) in the                          
                    Incident Command Center.  
 
 
Incident Commander  
Directly responsible for overall incident response. Assumes the duties of assignments not delegated (below). 
 
Safety Officer           
 
Responsible for the safety of property and personnel involved in incident response activities (normally safety           
                          manager). 
 
Communications Officer           
Responsible for establishing and maintaining the lines of communication between the Incident Command Center and 
incident response personnel. Accountable for the incident log. 
 
Staging Officer          
Sets up a staging area for equipment and personnel responding to the incident. Accountable for the control of          
      personnel and equipment into and out of the plant. 
 
Liaison Officer          
Acts as a liaison between the Incident Commander and other agencies.  
 
Public Information Officer  
        Responsible for the preparation and release of information to the public. 
 
Operations Chief           
Responsible for incident sc 
ene activities. Coordinates efforts of fire suppression & emergency response teams.  
 
Logistics Chief          
Acquires the resources needed to responds to (and recover from) the incident 
 
Planning Chief         
 Plans for the successful outcome of the incident. Prepares contingency plans. 
 
Finance Chief         
 Responsible for headcount, maintains records of costs incurred as a result of the incident. Also responsible for          
                     records protection. 
 
On-Scene Command _____________________________________ 
    ____________________________________  
 
Table 1: Incident Response - Responsibilities of the Incident Command Officers 
 
Incident Commander          
         Directly responsible for overall incident response.          
         Assumes the duties of assignments not delegated to the Incident Command Staff and Incident 
         Command Chiefs.          
     When required, initiates an evacuation.          
    Communicates the need for a community ev 
acuation to appropriate personnel. 
                  Approves the in-plant use of all responders who are not employees of the Burley plant. 
                  Responsible for communications with Corporate Management. 
 
Safety Officer           
 
    Responsible for the safety of property and personnel involved in incident response activities. 
                  Can bypass the normal lines of authority to ensure the safety of personnel or property. 
                  Monitors safety & emergency response equipment and communicates equipment needs to the            
         Logistics Chief. 
                 Monitors the safety awareness of responders. 
                 Works with responders to ensure that safe work practices are incorporated into incident response     
         activities. Be aware of emergency medical treatment, as found in appendices A, B and C, for 
         exposure to hazardous chemicals.  
 
Staging Officer          
         Accountable for the control of personn 
el & safety equipment into and out of the plant. 
                 Marshals incoming resources & maintains an inventory of non-committed resources. 
                 Sets up a staging area for equipment and personnel responding to the incident.          Makes sure that 
         outside responders report to staging area prior to entry into plant.   Makes sure that non-employee 
         responders do not enter plant without IC approval.   Contacts Liaison Officer if crowd or traffic 
         control support is needed from the Sheriff.  
 
Liaison Officer           
         Acts as a liaison between the Incident Commander and other agencies participating in incident 
         response. 
                  Provides the communication's link between IC and local, state and federal agencies. In particular, the 
         Sheriff's  Department & City/County Fire Departments. 
 
Public Information Officer        
           Assists with the development of community hazard notification or evacuat 
ion plans. 
                   Notifies (where necessary) the appropriate public officials. 
                   Issues any press releases or plant position statements concerning an emergency response action.  
                    Responsible for scheduling and providing communications training for key emergency response 
         team members.  
 
Communications Officer          
     Responsible for ensuring effective communications among all responders, agencies & IC staff. 
                  Sees that an incident log is maintained. 
                    Assess, manage and fulfill the communications needs of the incident responders.             
         Manage the plant telephone system during the incident.                            
 
Table 2: Incident Response - Responsibilities of the Incident Command Chiefs.  
 
Operations Chief 
              Advise the IC on the nature of the incident and the hazards involved.  
            Coordinate the efforts of and provide available resources 
and support to the On Scene Command and           
    incident responders (keep the IC informed of these resources & support). 
            Request the IC for additional resources needed to respond to the incident. 
            Implement action plans forwarded by the IC.  
           Advise the IC of the need to evacuate all or part of the plant.  
           Specific actions to be taken by the Operation Chief are indicated in the following table:  
 
Actions 
Completed 
 
 
Immediately contact environmental personnel if a spill or release is involved 
                           [     ] 
 
 
Communicate the need for non-plant responders (for example, City & County Fire Units) to the 
IC (These responders are to report to the staging area and wait for IC approval, prior to entering 
                         the plant.) 
 
                           [     ] 
 
 
 
Organize available resources (as needed) into an Operations Group. 
                           [     ] 
 
 
 
 
Planning Chief           
         Advise the IC of the hazards of the chemicals and processes which are (or might be) involved.          
         Advise the IC on the potential impact of the incident on other plant processes/areas.  
                  Advise the IC of actions necessary to minimize the overall impact of the incident on plant                  
 
 
 
 
 
 
               If a spill or release has occurred, determine the identity and quantity of released material. 
               Specific actions to be taken by the planning chief are indicated in the following table:  
 
 
Actions 
Completed 
 
 
Have the operations chief contact the On Scene Commander and inform him/her that the ICC has 
been set up and communicate the names of the IC chiefs and Officers 
                           [     ] 
 
 
Actively search out individuals who have knowledge of the incident and have them debriefed (for 
       example: the person who reported the incident.) 
                           [     ] 
 
 
Organize available individuals (as neede 
d) into a Planning Group (to include ESH personnel). 
                           [     ] 
 
                                                          
 
Table 2: Incident Response - Responsibilities of the Incident Command Chiefs. (Continued)  
 
 
Logistics Chief  
         Make arrangements for additional emergency personnel and equipment.  
           Make arrangements to ensure that a first aid station is adequately equipped and staffed.     
             Arrange for ambulance, Life Flight, or other transport for injured personnel.  
          Make arrangements for a temporary morgue.   
          Arrange for resources needed to re-commission the plant.  
          Arrange for resources needed to evacuate the plant. 
          Specific actions to be taken by the Logistics Chief are indicated in the following table: 
 
 
Action 
Completed 
 
 
Make sure that incoming phone calls are switched over to 
the IC center. 
                           [     ] 
 
 
          Ensure that the plant entrance is secured. 
                           [     ] 
 
 
              Contact the hospital (If needed.) 
                           [     ] 
 
 
Send help to assist with gate security, managing incoming calls and collecting contractor 
                          headcount. 
                           [     ] 
 
 
Organize available individuals (as needed) into a Logistics Group. 
                           [     ] 
 
 
 
 
Finance Chief  
         Arrange for the protection of plant records. 
            Arrange for funds needed t 
o respond to the incident. 
            Keep track of costs incurred during the incident. 
            Specific actions to be completed by the Finance Chief are indicated in the following table:  
 
 
Action 
Completed 
 
 
Complete a head count of visitor, guest, contractor and Sundance Personnel 
                           [     ] 
 
 
Organize available individuals (as needed) into a Finance Group 
                           [     ] 
 
                                                       7.0   TRAINING  
 
7.1   All new employees shall be trained on the requirements of this procedure before starting 
                               work. 
 
     7.2   Annual refresher training shall be conducted. 
 
7.3   Details on the requirements of fire extinguisher training can be found in the Fire 
                   P 
revention Procedure, No. 15. 
 
 
            8.0   DOCUMENTATION                    
 
8.1   All training records shall be kept for a minimum of three (3) years. 
 
8.2   See Training Procedure, No. 7, for details on documentation requirements 
                          Appendix A 
                      Emergency Response 
                         and Medical 
                             CS2 
 
 Preferred Name: CARBON DISULFIDE 
 
 
Regulatory Name: CARBON DISULFIDE 
 
 Chemical Source: NOEPA NOAA *:2813 
 
 NFPA Codes          F: 4 - Extremely flammable 
              H:2 - Hazardous - use breathing apparatUS 
                             R:0   Normally stable 
 
 
 
 General Description 
 Carbon bisulfide is a clear colorless to light yellow liquid with a strong disagreeable odor. It is 
 used in the manufacture of rayon and cellop 
hane, in the manufacture of flotation agents and as 
 a solvent. It has a flash point of -22 deg. F. and is flammable over a wide vapor air 
 concentration range. The vapors are readily ignited; the heat of a common light bulb may be 
 sufficient. It is heavier than water and insoluble in water. Its vapors are heavier than air. It 
 weighs 10.5 lbs/gallon. 
     (c)AAR, 1991) 
 
 Fire Hazard 
 Ignition temperature dangerously low: 212F. Vapors may be ignited by contact with ordinary 
 light bulb, when heated to decomposition, it emits highly toxic fumes of oxides of sulfur. 
 When heated to decomposition, emits highly toxic fumes of sulfur oxides and can react 
 vigorously with oxidizing materials. Avoid air, rust, halogens, metal azides, metals, oxidants; 
 when exposed to heat or flame reacts violently with aluminum, chlorine, azides, hypochlorite, 
 ethylamine diamine, ethylene imine, fluorine, metallic azides of lithium, potassium, cesium, 
 rubidium and sodium, nitrogen oxides, 
potassium1 zinc and (sulfuric acid plus permanganate). 
 Decomposes on standing for a long time. 
 
 (EPA, 1990) 
 
 Fire Fighting 
 If the vapor concentration exceeds 2 percent by volume or is unknown, self-contained 
 breathing mask with full face should be used by all persons entering contaminated area. Wear 
 special protective clothing. Isolate for 1/2 mile in all directions if tank car or truck is involved 
 in fire. 
 
Use dry chemical, carbon dioxide or other inert gas. Cooling and blanketing with water spray is 
effective in case of fires in metal containers or tanks to help prevent reignition by hot surfaces. 
Foam is ineffective except for very small, open spills involving fires. (EPA, 1990) 
 
 Protective Clothing 
 For emergency situations, wear a positive pressure, pressure-demand, full facepiece self- 
 contained breathing apparatus (SCBA) or pressure  demand supplied air respirator with 
 escape SCBA and a fully encapsulating~ chemical resistant suit. ((c)EPA, 1990) 
 
 
 
 
 
                      MATERIAL RATINGS______________ 
 
 
 AL PET/PVC 
        FABRIC< 1 hour 
 
 
 BARRICADE 
        FABRIC> 3 hours 
 
 
 BLUE MAX 
        FABRIC> 3 hours 
 
 
 BUTYL 
        FABRIC< 1 hour 
       GLOVES< 1 hour 
 
 
 BUTYL/NEOP 
        FABRIC< 1 hour 
 
 
 CHECKMATE 
        FABRIC> 3 hours 
 
 
 CHEMREL 
        FABRIC< 1 hour 
 
 
 CHEMREL MAX 
        FABRIC> 3 hours 
 
 
 CHEMTUFF 
        FABRIC< 1 hour 
 
 
 CPE 
        FABRIC< 1 hour 
 
 
 CPF III 
        FABRIC< 1 hour 
 
 
 FEP TEFLON 
        FACESHIELD1-3 hours 
 
 
 
 INTERCEPTOR 
        FABRIC> 3 hours 
 
 
 NAT RUB+NEOP 
        GLOVES< 1 hour 
 
 
 NEOP 
        FABRIC< 1 hour 
       GLOVES< 1 hour 
 
 
 NEOP/BUTYL 
        GLOVES< 1 hour 
 
 
 NI T+ POLYURETHANE+ PVC 
        BOOTS1-3 hours 
 
 
 NITRILE 
        GLOVES< 1 hour 
 
 
 PE 
        FABRIC< 1 hour 
 
 
 PE/EVAL/ PE 
        GLOVES> 3 hours 
 
 
 PET 
        FABRIC> 3 hours 
 
 
 POLYURETHANE+ PVC 
        BOOTS< 1 hour 
 
 
 PTFE TEFLON 
 
 
       FABRIC< 1 hour 
               PVAL 
 
                              GLOVES> 3 hours 
 
 
 PVC 
 
                              FABRIC< 1 hour 
                      GLOVES< 1 hour 
 
 RESPONDER 
 
           FABRIC         > 3 hours 
 
 
 SARANEX2 3P 
       FABRIC           < 1 hour 
 
 
 SILVER SHIELD 
      GLOVES        > 3 hours 
 
 
 VITON 
 
                         GLOVES> 3 hours 
 
 
           VITON/CHLOROBUTYL  
 
                         FABRIC           < 1 hour 
 
             VITON/NEOP 
 
                             FABRIC           > 3 hours 
 
 
 
 Non Fire Response 
 Keep sparks, flames, and other sources of ignition away. Keep material out of water sources 
 and sewers. Build dikes to contain flow as necessary. Attempt to stop leak if without undue 
 personnel hazard. Use water spray to knock-down vapors. Combustion products include 
 corrosive or toxic vapors. Land spill: Dig a  
pit, pond, lagoon, holding area to contain liquid or 
 solid material. Dike surface flow using soil, sand bags, foamed polyurethane, or foamed 
 concrete. Absorb bulk liquid with fly ash or cement powder. Apply approriate foam to 
 diminish vapor and fire hazard. Water spill: 
 Neutralize with agricultural lime (CaO), crushed limestone (CaCO3), or sodium bicarbonate 
 (NaHCO3) If dissolved, in region of 10 ppm or greater concentration, apply activated carbon at 
 ten times the spilled amount. Use mechanical dredges or lifts to remove immobilized masses 
 of pollutants and precipitates. ((c) AAR, 1991) 
 
 Health Hazard 
 The material affects the central nervous system, cardiovascular system, eyes, kidneys, liver, 
 and skin. It may be absorbed through the skin as a vapor or liquid, inhaled or ingested. The 
 probable oral lethal dose for a human is between 0.5 and 5 g/kg or between 1 ounce and 1 pint 
 (or 1 pound) for a 70 kg (150 lb.) person. In chronic 
 exposures, the central nervo 
us system is damaged and results in the disturbance of vision and 
 sensory changes as the most common early symptoms. Lowest lethal dose for humans has been 
 reported at 14 mg/kg or 0.98 grams for a 70 kg person. Alcoholics and those suffering from 
 neuropsychic trouble are at special risk. (EPA, 1990) 
 
 
 
 
 
 
 
 
 Properties 
 
 
             Flash Point: 22 F (cc) (EPA, 1990) 
 
 
                                Lower Exp Limit:1 % (EPA, 1990) 
                         Upper Exp Limit:            50% (EPA, 1990) 
         Auto Igtn Temp:            212F (USCG, 1991) 
         Melting Point:            -167F (EPA, 1990) 
         Vapor Pressure:            360mm at 77 F (EPA, 1990) 
 
                                              Vapor Density (air 1):2.67 (EPA, 1990) 
 
 
                                              Specific Gravity, Liquid:1.2632 at 68 F (EPA, 1990) 
 
 
                            Boiling Point:116 F at 760 m 
m (EPA, 1990) 
 
 
                                Molecular weight:76.13 (EPA, 1990) 
 
 
              IDLH:500 ppm (NIOSH, 1994) 
 
 
                  TLV TWA:10 ppm Skin. ((c)ACGIH, 1991) 
 
 First Aid 
         Warning:Effects may be delayed. Caution is advised. 
 
 
 Signs and Symptoms of Acute Carbon Disulfide Exposure: Acute exposure to carbon disulfide 
 primarily affects the central nervous system producing signs and symptoms that may include 
 headache, dizziness, difficulty swallowing, nervousness, tremors, mental depression, delirium, 
 psychosis, convulsions, paralysis, and coma. Nausea, vomiting, cyanosis (blue tint to skin and 
 mucous membranes), hypothermia (low body temperature), and peripheral vascular collapse 
 may also occur. Respiratory effects include coughing, dyspnea (shortness of breath), and 
 respiratory failure. Carbon disulfide is a strong skin irritant; dermal exposure may result in 
 severe burns. Eye exposu 
re may cause degeneration of the retina and optic nerve. Pupils may 
 be dilated. 
 
 Emergency Life-Support Procedures: Acute exposure to carbon disulfide may require 
 decontamination and life support for the victims. Emergency personnel should wear protective 
 clothing appropriate to the type and degree of contamination. Air-purifying or supplied air 
 respiratory equipment should also be worn, as necessary. Rescue vehicles should carry supplies 
 such as plastic sheeting and disposable plastic bags to assist in preventing spread of 
 contamination. 
 
 
 
 
 
 Inhalation Exposure: 
 
          1.Move victims to fresh air. Emergency personnel should avoid self exposure to 
    carbon disulfide. 
      2.Evaluate vital signs including pulse and respiratory rate, and note any trauma. 
    If no puls 
e is detected, provide CPR. If not breathing, provide artificial 
 respiration. If breathing is labored, administer oxygen or other respiratory support. 
      3.Obtain authorization and/or further instructions from the local hospital for 
    administration of an antidote or performance of other invasive procedures. 
      4.Transport to a health care facility. 
 
 
 Dermal/Eye Exposure: 
      1.Remove victims from exposure. Emergency personnel should avoid self- exposure to 
    carbon disulfide. 
      2.Evaluate vital signs including pulse and respiratory rate, and note any trauma. 
    If no pulse is detected, provide CPR. If not breathing, provide artificial 
 respiration. If breathing is labored, administer oxygen or other respiratory support. 
      3.Remove contaminated clothing as soon as possible. 
         4.If eye exposure has occurred, eyes must be flushed with lukewarm water for at 
    least 15 minutes. 
      5.Wash exposed skin areas three times. Wash initially wit 
h soap and water follow 
    with an alcohol wash, then wash again with soap and water. 
      6.Obtain authorization and/or further instructions from the local hospital for 
    administration of an antidote or performance of other invasive procedures. 
      7.Transport to a health care facility. 
 
 
 Ingestion Exposure: 
      1.Evaluate vital signs including pulse and respiratory rate, and note any trauma. 
    If no pulse is detected, provide CPR. If not breathing, provide artificial 
 respiration. If breathing is labored, administer oxygen or other respiratory support. 
      2.Obtain authorization and/or further instructions from the local hospital for 
    administration of an antidote or performance of other invasive procedures. 
      3.Give the victims water or milk: Children up to 1 year old, 125 mL (4 oz or 1/2 
    cup); children 1 to 12 years old, 200 mL (6 oz or 3/4 cup); adults, 250 mL (8 oz or 1 
 cup). Water or milk should be given only if victims are conscious an 
d alert. 
      4.Activated charcoal may be administered if victims are conscious and alert. Use 15 
    to 30 g (1/2 to 1 oz) for children, 50 to 100 g (1 3/4 to 3 1/2 oz) for adults, with 
 125 to 250 mL (1/2 to 1 cup) of water. 
      5.Promote excretion by administering a saline cathartic or sorbitol to conscious and 
    alert victims. Children require 15 to 30 g (1/2 to 1 oz) of cathartic; 50 to 100 g 
 (1 3/4 to 3 1/2 oz) is recommended for adults. 
      6.Transport to a health care facility. (EPA, 1990) 
 
 
 
                           Appendix B 
                      Emergency Response 
                         and Medical 
                       Monomethylamine 
 
 Preferred Name: METHYLAMINE 
 
Regulatory Name: METHANAMINE 
                           MONOMETHYLAMINE 
                            Chemical Source: NOEPANOAA#.  :8850 
 
   NFPA Codes         F: 4 - Extremely flammable 
              H:  3 - Extremely hazardous - use full protection 
                          R: 
0 - Normally stable 
 
 
 
 General Description 
 Methylamine, anhydrous is a colorless flammable gas that is shipped under pressure as a 
 liquid. It has a pungent fishy odor that may resemble ammonia at higher concentrations. It is 
 used for making pharmaceuticals~ insecticides, paint removers, surfactants, rubber chemicals, 
 and various other products. It is irritating and corrosive to bodily tissue. The gas is heavier 
 than air and may collect in low-lying areas. It is easily ignited under most ambient temperature 
 conditions. Its boiling point of 20.3 deg. F. indicates that Methylamine will boil or otherwise 
 evaporate rapidly upon release. It is very soluble in water and does not react. Vapor of the 
 product are heavier than air, may travel a considerable distance to a source of ignition and 
 flash back. Vapors may persist in pits, hollows, and depressions. Accumulation of vapor or gas 
 in confined spaces such as buildings or sewers, may explode if ignited. Con 
tainers may 
 rupture violently if exposed to fire or excessive heat for sufficient time. The product weighs 
 approximately 5.8 lbs/gallon. ((C) AAR, 1991) 
 
 Fire Hazard 
 FLAMMABLE. POISONOUS GASES MAY BE PRODUCED IN FIRE. Containers may 
 explode in fire. Flashback along vapor trail may occur. Vapor may explode if ignited in an 
 enclosed area. Toxic nitrogen oxides may be formed. Vapors are heavier than air and may 
 travel considerable distance to a source of ignition and flash back. (USCG, 1991) 
 
 Fire Fighting 
 Do not extinguish fire unless flow can be stopped. Use water in flooding quantities as fog. 
 Cool all affected containers with flooding quantities of water. Apply water from as far a 
 distance as possible. ((c) AAR, 1991) 
 
 Protective Clothing 
 Wear goggles and self-contained breathing apparatus. (USCG, 1991) 
 
 
 
 
                         MATERIAL RATINGS______________ 
                 CHEMREL 
                     FABRIC          <1 HOUR 
 
 
 
     NAT RUB 
                           GLOVES< 1 hour 
 
 
 NEOP 
        GLOVES       > 3 hours 
 
 
 NITRILE 
        GLOVES          > 3 hours 
 
 
 PTFE TEFLON 
        FABRIC            > 3 hours 
 
 
 PVC 
        GLOVES           1 - 3 hours 
 
 
 
 
 
                 Non Fire Response 
 Keep sparks, flames, and other sources of ignition away. Keep material out of water sources 
 and sewers. Attempt to stop leak if without undue personnel hazard. Use water spray to knock- 
 down vapors. Vapor knockdown water is corrosive or toxic and should be diked for 
 containment. Land spill: Dig a pit, pond, lagoon, holding area to contain liquid or solid 
 material. Dike surface flow using soil, sand bags, foamed polyurethane, or foamed concrete. 
 Absorb bulk liquid with fly ash, 
cement powder, or commercial sorbents. Neutralize with 
 sodium bisulfate (NaHSO4) . Water spill: Use natural barriers or oil spill control booms to 
 limit spill travel. Use surface active agent (e.g. detergent, soaps, alcohols), if approved by 
 EPA. Inject "universal" gelling agent to solidify encircled spill and increase effectiveness of 
 booms. If dissolved, in region of 10 ppm or greater concentration, apply activated carbon at 
 ten times the spilled amount. Add sodium bisulfate (NaHSO4) . Use mechanical dredges or 
 lifts to remove immobilized masses of pollutants and precipitates. ((c) AAR, 1991) 
 
 Health Hazard 
 VAPOR: Irritating to eyes, nose and throat. If inhaled will cause coughing or difficult breathing. 
 LIQUID: Will burn skin and eyes. (USCG, 1991) 
 
 Properties 
              Flash Point:Not Applicable. Flammable, liquefied compressed gas. (USCG, 1991) 
 
 
                                  Lower Exp Limit:4.3 % (USCG, 1991) 
 
 
 
                            Upper Exp Limit:21 % (USCG, 1991) 
 
 
                              Auto Igtn Temp:806 F (USCG, 1991) 
 
 
                              Melting Point: 134.5 F (USCG, 1991) 
 
 
                              Vapor Pressure:1972.92 mm at 60 F (USCG, 1991) 
 
 
                                              Vapor Density (air = 1):1.1 (USCG, 1991) 
 
 
                                              Specific Gravity, Liquid:0.693 at 20.3 F (USCG, 1991) 
 
 
                              Boiling Point:20.3 F at 760 mm (USCG, 1991) 
 
 
                                  Molecular Weight:31.1 (USCG, 1991) 
 
 
              IDLH:100 ppm (NIOSH, 1994) 
 
 
                    TLV TWA:10 ppm ((c)ACGIH, 1991) 
 
 First Aid 
 
 If this chemical contacts the eyes immediately wash the eyes with large amounts of water, 
 occasionally l 
ifting the lower and upper lids. Get medical attention immediately. Contact 
 lenses should not be worn when working with this chemical. (solution) . If eye tissue is frozen, 
 seek medical attention immediately; if tissue is not frozen, immediately and thoroughly flush 
 the eyes with large amounts of water for at least 15 minutes, occasionally lifting the lower and 
 upper eyelids. If irritation, pain, swelling, lacrimation, or photophobia persist, get medical 
 attention as soon as possible. 
 If this chemical contacts the skin, immediately flush the contaminated skin with water. If this 
 chemical penetrates the clothing, immediately remove the clothing and flush the skin with 
 water. Get medical attention promptly. (solution) . If frostbite has occurred, seek medical 
 attention immediately; do NOT rub the affected areas or flush them with water. In order to 
 prevent further tissue damage, do NOT attempt to remove frozen clothing from frostbitten 
 areas. If frostbite has NOT oc 
curred, immediately and thoroughly wash contaminated skin 
 with soap and water. 
 If a person breathes large amounts of this chemical, move the exposed person to fresh air at 
 once. If breathing has stopped, perform mouth-to-mouth resuscitation. Keep the affected 
 person warm and at rest. Get medical attention as soon as possible. If this chemical has been 
 swallowed, get medical attention immediately. (solution) 
 (NIOSH, 1994) 
                                                                                                                         Appendix C 
                      Emergency Response 
                         and Medical 
                  Sodium Hydroxide (Caustic) 
 
 preferred Name: SODIUM HYDROXIDE 
 
 Regulatory Name: SODIUM HYDROXIDE 
 
Chemical Source: NOEPA                   NOAA 41:9073 
 
 NFPA Codes           F: 0 - Will not burn 
            H: 3 - Extremely hazardous - use full protection  
                       R: 1 - Unstable if heated - use normal p 
recautions 
 
 
 
 General Description 
 Sodium hydroxide, dry is a white material. It is used in chemical manufacturing, petroleum 
 refining, cleaning compounds, home drain openers, and for many other uses. It is soluble in 
 water with release of heat. It absorbs moisture from the air and dissolves in it. It is corrosive to 
 metals and tissue. ((c) AAR, 1991) 
 
 
Fire Hazard 
 Not flammable. May cause fire on contact with combustibles. Flammable gas may be produced 
 on contact with metals. (USCG, 1991) 
 
Fire Fighting 
 Extinguish fire using agent suitable for type of surrounding fire (material itself 
 does not burn or burns with difficulty) . Use water in flooding quantities as fog. 
 Apply water from as far a distance as possible. ((c) AAR, 1991) 
 
Protective Clothing 
 Wear rubber overclothiflg (including gloves) . (USCG, 1991) 
 
 
                       8: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                       MATERIAL RATINGS______________ 
 
 
 
                AL PET/PVC 
 
           FABR IC     > 3 hours 
 
 BLUE MAX 
 
           FABRIC      > 3 hours 
 
 BUTYL 
      FABRIC       > 3 hours 
           GLOVES     > 3 hours 
 
 
 BUTYL/NEOP 
      FABRIC      > 3 hours 
 
 
 CHEMREL 
 
                   FABRIC        > 3 hours 
 
 CHEMTUFF 
                     FABRIC            > 3 hours 
 
 
 CPE 
                  FABRIC          > 3 hours 
                GLOVES         > 3 hours 
 
 NAT RTJB+NEOP+NBR 
 
                  GLOVES         > 3 hours 
 
 
 NEOP 
                    FABRIC           > 3 hours 
                 GLOVES          > 3 hours 
 
 
 NEOP/BUTYL 
                  GLOVES          > 3 hours 
 
 
 NI TRILE+ PVC 
                   FABRIC            > 3 hours 
 
 
 POLYURETHANE 
                 GLOVES               > 3 hours 
 
 
 PTFE TEFLON 
              FABRIC               > 3 hours 
 
 
 PVC 
              FABRIC               > 3 hours 
 
 
 RESPONDER 
 
        FABRIC              > 3 hours 
 
 
 SARINEX2 3P 
                FABRIC                  > 3 hours 
 
 
 VI TON/ CHLOROBUTYL 
                                                                 FABRIC            > 3 hours 
 
 
 VI TON/NEOP 
      FABRIC      > 3 hours 
 
 
     Non-Fire Response 
 Keep material out of water sources and sewerS. Land spill:   Dig a pit, pond, lagoon, holding area 
 to contain liquid or solid material. Cover solids with a plastic sheet to prevent dissolving in 
 rain or fire fighting water. Water spill: Neutralize with dilute acid. ((c) AAR, 1991) 
 
 
Health Hazard 
 DUST: Irritating to eyes, nose and throat. SOLID: Will burn if swallowed. (USCG, 1991) 
                                                      skin and eyes. 
                                                     properties 
                        Flash Point:Not Applicable. Not flammable. (USCG, 1991) 
 
 
 
         Lower Exp Limit:Not Applicable. Not flammable. (USCG, 1991) 
 
 
                                Upper Exp Limit:Not Applicable. Not flammable. (USCG, 1991) 
 
 
                              Auto Igtn Temp:Not Applicable. Not flammable. (USCG, 1991) 
 
 
                              Melting Point:604 F (USCG, 1991) 
 
 
                              Vapor Pressure:Not Applicable. (USCG, 1991) 
 
 
                                              Vapor Density (air = 1):Not Applicable. (USCG, 1991) 
 
 
                                              Specific Gravity, Solid:2.13 at 68 F (USCG, 1991) 
 
 
                              Boiling Point:Very high. (USCG, 1991) 
 
 
                                Molecular Weight:40 (USCG, 1991) 
 
 
 IDLH: 10 mg/m3 (NIOSH, 1994) 
 
                  TLV TWA:2 mg/m3 Ceiling limit. ((c)ACGIH, 1991) 
 
 
First Aid 
 If this chemical contacts the eyes, immediately wash the eyes with large amounts of water, 
 occasionally lifting the lower and upper lids. Get medical attention immediately. Contact 
 lenses should not be worn when working with this chemical. If this chemical contacts the skin, 
 immediately flush the contaminated skin with water. If this chemical penetrates the clothing, 
 immediately remove the clothing and flush the skin with water. Get medical attention 
 promptly. 
 If a person breathes large amounts of this chemical, move the exposed person to fresh air at 
 once. If breathing has stopped, perform mouth to-mouth resuscitation. Keep the affected 
 person warm and at rest. Get medical attention as soon as possible. If this chemical has been 
 swallowed, get medical attention immediately. (NIOSH, 1994)
Click to return to beginning